PRECAUTION FOR USING R290 REFRIGERANT

 

• pay careful attention to the following points:

 

 WARNING

The mixing of different refrigerants within a system is prohibited.

Operation, maintenance, repairing and refrigerant recovery should be carried out by trained and certifi ed personnel in the use of fl ammable 
refrigerants and as recommended by the manufacturer. Any personnel conducting an operation, servicing or maintenance on a system or 
associated parts of the equipment should be trained and certifi ed.

Any part of refrigerating circuit (evaporators, air coolers, AHU, condensers or liquid receivers) or piping should not be located in the proximity of 
heat sources, open fl ames, operating gas appliance or an operating electric heater.

The user/owner or their authorized representative shall regularly check the alarms, mechanical ventilation and detectors, at least once a year, 
where as required by national regulations, to ensure their correct functioning.

A logbook shall be maintained. The results of these checks shall be recorded in the logbook.

In case of ventilations in occupied spaces shall be checked to confi rm no obstruction.

Before a new refrigerating system is put into service, the person responsible for placing the system in operation should ensure that trained and 
certifi ed operating personnel are instructed on the basis of the instruction manual about the construction, supervision, operation and maintenance 
of the refrigerating system, as well as the safety measures to be observed, and the properties and handling of the refrigerant used.

The general requirement of trained and certifi ed personnel are indicated as below:
a)

Knowledge of legislation, regulations and standards relating to fl ammable refrigerants; and,

b)

 

Detailed knowledge of and skills in handling fl ammable refrigerants, personal protective equipment, refrigerant leakage prevention, handling 
of cylinders, charging, leak detection, recovery and disposal; and,

c)

Able to understand and to apply in practice the requirements in the national legislation, regulations and Standards; and,

d)

Continuously undergo regular and further training to maintain this expertise.

Ensure protection devices, refrigerating circuit and fi ttings are well protected against adverse environmental effects (such as the danger of water 
collecting and freezing in relief pipes or the accumulation of dirt and debris).

 CAUTION

1. Installation (Space)

 

• Must comply with national gas regulations, state municipal rules and legislation. Notify relevant authorities in accordance with all applicable 

regulations.

 

• Must ensure mechanical connections be accessible for maintenance purposes.

 

• In cases that require mechanical ventilation, ventilation openings shall be kept clear of obstruction.

 

• When disposal of the product, do follow to the precautions in #12 and comply with national regulations.

 

• Always contact to local municipal offi ces for proper handling.

2. Servicing

2-1. Service personnel

 

• Any qualifi ed person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certifi cate from an 

industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry 
recognized assessment specifi cation.

 

• Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other 

skilled personnel shall be carried out under the supervision of the person competent in the use of fl ammable refrigerants.

 

• Servicing shall be performed only as recommended by the manufacturer.

 

• The system is inspected, regularly supervised and maintained by a trained and certifi ed service personnel who is employed by the person user 

or party responsible.

 

• Ensure refrigerant charge not to leak.

2-2. Work

 

• Prior to beginning work on systems containing fl ammable refrigerants, safety checks are necessary to ensure that the risk of ignition is 

minimised. 
For repair to the refrigerating system, the precautions in #2-2 to #2-8 must be followed before conducting work on the system.

 

• Work shall be undertaken under a controlled procedure so as to minimize the risk of a fl ammable gas or vapour being present while the work 

is being performed.

 

• All maintenance staff and others working in the local area shall be instructed and supervised on the nature of work being carried out.

 

• Avoid working in confi ned spaces. Always ensure away from source, at least 2 meter of safety distance, or zoning of free space area of at 

least 2 meter in radius.

 

• Wear appropriate protective equipment, including respiratory protection, as conditions warrant.

 

• Keep all sources of ignition and hot metal surfaces away.

2-3. Checking for presence of refrigerant

 

• The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially 

fl ammable atmospheres.

 

• Ensure that the leak detection equipment being used is suitable for use with fl ammable refrigerants, i.e. non sparking, adequately sealed or 

intrinsically safe.

 

• In case of leakage/spillage happened, immediately ventilate area and stay upwind and away from spill/release.

 

• In case of leakage/spillage happened, do notify persons down wind of the leaking/spill, isolate immediate hazard area and keep unauthorized 

personnel out.

Содержание WH-WDG05LE5

Страница 1: ... be installed The caution items stated here must be followed because these important contents are related to safety The meaning of each indication used is as below Incorrect installation due to ignoring or negligence of the instruction will cause harm or damage and the seriousness is classified by the following indications Please leave the installation manual with the unit after installation WARNI...

Страница 2: ...eakage during operation Extinguish all fire sources if present It may lead to the risk of fire or explosion when the refrigerant contacts with fire Only use the supplied or specified installation parts else it may cause unit vibrate loose water leakage electrical shock or fire If there is any doubt about the installation procedure or operation always contact the authorized dealer for advice and in...

Страница 3: ...ations Must ensure mechanical connections be accessible for maintenance purposes In cases that require mechanical ventilation ventilation openings shall be kept clear of obstruction When disposal of the product do follow to the precautions in 12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel Any qualified person ...

Страница 4: ...charging recovering or purging the system That there is continuity of earth bonding At all times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufacturer s technical department for assistance If a fault exists that could compromise safety then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with If the faul...

Страница 5: ...re is ventilation available 9 Charging procedures In addition to conventional charging procedures the following requirements shall be followed Ensure that contamination of different refrigerants does not occur when using charging equipment Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them Cylinders shall be kept in an appropriate position accordin...

Страница 6: ...ings and in good condition Before using the recovery machine check that it is in satisfactory working order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the re...

Страница 7: ...d this outdoor unit There must be no building openings windows doors light shafts cellar entrances escape hatches flat roof windows or ventilation openings in the protective zone There must be no ignition sources such as heat above 360 C sparks open flame plug sockets light switches lamps electrical switches or other permanent ignitions sources in the protective zone The protective zone must not e...

Страница 8: ...to tighten the hose at drain hose connector to prevent it from leaking Drain elbow 1 Rubber cap 2 After selecting the best location start installation according to Installation Diagram 1 When installing at roof please consider strong wind and earthquake Please fasten the installation stand firmly with bolt or nails 2 When installing to a concrete or solid surface use M10 or a W 3 8 bolts and nuts ...

Страница 9: ...ate Fig 4 1 2 Remove the terminal cover and cable gland cap Fig 4 2 3 Insert the cabtyre cable 1 Fig 4 3 4 4 Pulled in from the rear panel and inserted from the bottom of the electric controller BOX 4 Connect to terminal block Fig 4 5 5 Fasten the cable gland 2 Fig 4 4 6 Set the terminal cover 2 Fig 4 2 7 Set the front plate Fig 4 1 From Indoor unit Fig 4 3 Fig 4 1 Fig 4 2 Tightening torque 147 1 ...

Страница 10: ... 2 Remove the 3 screws Fasten the 3 screws Insert 4 claws WARNING This equipment must be properly earthed Terminals on the indoor unit 1 2 3 Colour of wires Terminals on the outdoor unit 1 2 3 Terminal screw Tightening torque cN m kgf cm M4 157 196 16 20 M5 196 245 20 25 1 2 3 Earth Wire must be longer than other wires for safety reason Screw Cable gland 5 mm or more gap between wires Indoor outdo...

Отзывы: