Required tools for Installation Works

1  Phillips screw driver
2 Level 

gauge

3  Electric drill, hole core drill 
4 Hexagonal 

wrench 

(4 mm)

5 Spanner
6 Pipe 

cutter

7 Reamer
8 Knife
9  Gas leak detector
10 Measuring tape
11 Thermometer
12 Megameter

13 Multimeter
14 Torque wrench

18 N•m (1.8 kgf•m)
42 N•m (4.3 kgf•m)
55 N•m (5.6 kgf•m)
65 N•m (6.6 kgf•m)
100 N•m (10.2 kgf•m)

15 Hand gloves
(for refrigerant circuit repair
16 Vacuum pump
17 Gauge manifold
18 Recovery machine
19 Recovery cylinder)

 CAUTION

R290

REFRIGERANT

This AIR-TO-WATER HEATPUMP contains 

and operates with refrigerant R290.

THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED 

BY QUALIFIED PERSONNEL.

Refer to National, State, Territory and local legislation, 

regulations, codes, installation & operation manuals, before 

the installation, maintenance and/or service of this product.

Explanation of symbols displayed on the indoor unit or outdoor unit.

WARNING

This symbol shows that this equipment uses 
a fl ammable refrigerant with safety A3 group 
per ISO 817. If the refrigerant is leaked, 
together with an external ignition source, 
there is a possibility of fi re/explosion.

CAUTION

This symbol shows that the Installation 
Manual should be read carefully.

CAUTION

This symbol shows that a service personnel 
should be handling this equipment with 
reference to the Installation Manual.

CAUTION

This symbol shows that there is information 
included in the Operation Manual and/or 
Installation Manual.

Installation Manual

AIR-TO-WATER HEATPUMP OUTDOOR UNIT

WH-WDG05LE5, WH-WDG07LE5,
WH-WDG09LE5

SAFETY PRECAUTIONS

 

• Read the following “SAFETY PRECAUTIONS” carefully before installation.

 

• Electrical work and water installation works must be done by licensed electrician and licensed water system installer respectively. Be sure 

to use the correct rating and main circuit for the model to be installed.

 

• The caution items stated here must be followed because these important contents are related to safety. The meaning of each indication 

used is as below. Incorrect installation due to ignoring or negligence of the instruction will cause harm or damage, and the seriousness is 
classifi ed by the following indications.

 

• Please leave the installation manual with the unit after installation.

 

 WARNING

This indication shows the possibility of causing death or serious injury.

 

 CAUTION

This indication shows the possibility of causing injury or damage to properties only.

The items to be followed are classifi ed by the symbols:

Symbol with white background denotes item that is PROHIBITED.

   

Symbol with dark background denotes item that must be carried out.

 

• Carry out test running to confi rm that no abnormality occurs after the installation. Then, explain to user the operation, care and 

maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.

 

• This appliance is not intended for accessibility by the general public.

 

• If there is any doubt about the installation procedure or operation, always contact the authorized dealer for advice and information.

 WARNING

Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. Any unfi t method or 
using incompatible material may cause product damage, burst and serious injury.

Do not install outdoor unit near handrail of veranda. When installing outdoor unit at veranda of high rise building, child may climb up to outdoor 
unit and cross over the handrail and causing accident.

Do not use unspecifi ed cord, modifi ed cord, joint cord or extension cord for power supply cord. Do not share the single outlet with other electrical 
appliances. Poor contact, poor insulation or over current will cause electrical shock or fi re.

Do not tie up the power supply cord into a bundle by band. Abnormal temperature rise on power supply cord may happen.

WEB-ACXF60-51540-EN

ENGLISH

Содержание WH-WDG05LE5

Страница 1: ... be installed The caution items stated here must be followed because these important contents are related to safety The meaning of each indication used is as below Incorrect installation due to ignoring or negligence of the instruction will cause harm or damage and the seriousness is classified by the following indications Please leave the installation manual with the unit after installation WARNI...

Страница 2: ...eakage during operation Extinguish all fire sources if present It may lead to the risk of fire or explosion when the refrigerant contacts with fire Only use the supplied or specified installation parts else it may cause unit vibrate loose water leakage electrical shock or fire If there is any doubt about the installation procedure or operation always contact the authorized dealer for advice and in...

Страница 3: ...ations Must ensure mechanical connections be accessible for maintenance purposes In cases that require mechanical ventilation ventilation openings shall be kept clear of obstruction When disposal of the product do follow to the precautions in 12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel Any qualified person ...

Страница 4: ...charging recovering or purging the system That there is continuity of earth bonding At all times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufacturer s technical department for assistance If a fault exists that could compromise safety then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with If the faul...

Страница 5: ...re is ventilation available 9 Charging procedures In addition to conventional charging procedures the following requirements shall be followed Ensure that contamination of different refrigerants does not occur when using charging equipment Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them Cylinders shall be kept in an appropriate position accordin...

Страница 6: ...ings and in good condition Before using the recovery machine check that it is in satisfactory working order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the re...

Страница 7: ...d this outdoor unit There must be no building openings windows doors light shafts cellar entrances escape hatches flat roof windows or ventilation openings in the protective zone There must be no ignition sources such as heat above 360 C sparks open flame plug sockets light switches lamps electrical switches or other permanent ignitions sources in the protective zone The protective zone must not e...

Страница 8: ...to tighten the hose at drain hose connector to prevent it from leaking Drain elbow 1 Rubber cap 2 After selecting the best location start installation according to Installation Diagram 1 When installing at roof please consider strong wind and earthquake Please fasten the installation stand firmly with bolt or nails 2 When installing to a concrete or solid surface use M10 or a W 3 8 bolts and nuts ...

Страница 9: ...ate Fig 4 1 2 Remove the terminal cover and cable gland cap Fig 4 2 3 Insert the cabtyre cable 1 Fig 4 3 4 4 Pulled in from the rear panel and inserted from the bottom of the electric controller BOX 4 Connect to terminal block Fig 4 5 5 Fasten the cable gland 2 Fig 4 4 6 Set the terminal cover 2 Fig 4 2 7 Set the front plate Fig 4 1 From Indoor unit Fig 4 3 Fig 4 1 Fig 4 2 Tightening torque 147 1 ...

Страница 10: ... 2 Remove the 3 screws Fasten the 3 screws Insert 4 claws WARNING This equipment must be properly earthed Terminals on the indoor unit 1 2 3 Colour of wires Terminals on the outdoor unit 1 2 3 Terminal screw Tightening torque cN m kgf cm M4 157 196 16 20 M5 196 245 20 25 1 2 3 Earth Wire must be longer than other wires for safety reason Screw Cable gland 5 mm or more gap between wires Indoor outdo...

Отзывы: