73
12.18 Holiday Mode
Purpose:
Promotes energy saving by allowing the user to stop the system during holiday and enables the system to
resume at the preset temperature after holiday.
Control
details:
o
Range of days can be set in holiday mode is from 1 to 999 days.
o
After days of holiday have been set, heat pump will stop and only resume operation at 12.00am at the
end of holiday countdown.
Start
condition:
o
Unit is OFF and holiday mode is set.
* The day the holiday mode was set is counted as day 1.
Stop
condition:
o
OFF/ON button is pressed.
o
Holiday counter is reached.
12.19 Dry Concrete Function
Purpose
Provide heat to floor heating panel and dry the wet concrete during installation.
Setting
condition:
o
Dry concrete parameter can be set through control panel by selecting dry concrete menu.
o
Parameters are possible to set up to 99 days with different target set temperature.
Control
details:
o
Dry concrete operation can be activate under Service Mode 3.
o
Once dry concrete function start, day 1 setting temperature will be send to indoor unit by control panel.
o
Unit will operate heat mode with dry concrete preset water outlet temperature. (No shift value added to
the preset water outlet temperature)
o
After complete day 1 setup operation, day 2 data will be send to indoor at 12.00am on the second day.
o
Each preset data will be send everyday until dry concrete mode is complete, unit will turns OFF and exit
dry concrete function.
o
3 ways valve and booster heater will turn OFF and 2 ways valve will turns ON.
Cancel
condition:
o
Unit will turns OFF and exit dry concrete function.
o
OFF signal is received by pressing OFF/ON button or error H76 is occurred.
Содержание WH-SHF09F3E5
Страница 19: ...19 4 2 Outdoor Unit Air inlet rear Air outlet Air inlet side ...
Страница 32: ...32 10 1 2 Solar Printed Circuit Board Optional ...
Страница 48: ...48 67 C 67 C 60 C 65 C 63 C 67 C 67 C ...
Страница 49: ...49 60 C 60 C 65 C 65 C 72 C ...
Страница 55: ...55 67 C 67 C 67 C 67 C ...
Страница 56: ...56 67 C 67 C 60 C 60 C 55 C 75 C ...
Страница 57: ...57 67 C 67 C 60 C 60 C 55 C 75 C ...
Страница 138: ...138 19 2 WH UH09FE5 WH UH12FE5 50 53 55 56 54a 61 60 25 59 57 58 55 56 54 66 54a 50a 50a 58 64 28 65 62 62 22 46 ...
Страница 139: ...139 2 4 1 8 7 6 9 3 21 70 70 73 23 13 68 10 4 20 5 4a 4a 19 18 12 11 13 24 27a 74 74 26 16 27 15 ...