110
16.5.24 Output Over Current Detection (F23)
Malfunction Decision Conditions:
During operation of heating, when outdoor DC current is above 54A
is detected by the IPM DC Peak
sensing circuitry in the outdoor unit PCB (main).
Malfunction Caused:
1 Faulty outdoor unit PCB (main).
2 Faulty
compressor.
Abnormality Judgment:
Continue for 7 times.