92
13.16 Three Ways Valve Control
Purpose:
- 3 ways valve is used to change flow direction of hot water from heat pump between heating side and tank side.
Control contents:
1 3 ways valve switch Off:
o
During 3 ways valve switch Off time, the hot water will provide heat capacity to heating side.
2 3 ways valve switch On:
o
During 3 ways valve switch On time, the hot water will provide heat capacity to tank side.
3 Stop
condition:
o
During stop mode, 3 ways valve will be in switch off position.
L
N2
Indoor Unit
N1
Spring Return 2 point
SPDT 3 wire
7
6
M
L
8
N1
7
N2
COM
Open
Close
6
6: Terminal Bord No.
M
L
NC
8
N1
7
N2
6
M
L
NO
8
N1
7
N2
6
8
AC230V
* During pump down and force mode, fix 3 ways valve in close condition.
* Recommended Parts : SFA 21/18 (Siemens)
13.17 Two Ways Valve Control
Functionality of 2 ways valve:
Use to allow hot water to floor heating panel or block cold water to floor heating panel.
Control contents:
1 When indoor running in heat mode, OPEN the 2 ways valve.
2 When indoor running in cool mode, CLOSE the 2 ways valve.
3 Stop
condition:
a.
During stop mode, fix 2 ways valve in close condition.
L
N2
Indoor Unit
N1
Spring Return 2 point
SPDT 3 wire
4
3
M
L
5
N1
4
N2
COM
Open
Close
3
3: Terminal Bord No.
M
L
NC
5
N1
4
N2
3
M
L
NO
5
N1
4
N2
3
5
AC230V
* During pump down mode, fix 2 ways valve in close condition.
* During force mode, open 2 ways valve.
* Recommended Parts : SFA 21/18 (Siemens)
Содержание WH-SDC12F6E5
Страница 24: ...24 4 2 Outdoor Unit Air inlet rear Air outlet Air inlet side ...
Страница 35: ...35 10 1 2 Solar Printed Circuit Board Optional ...
Страница 63: ...63 57 C 57 C 57 C 57 C ...
Страница 64: ...64 ...
Страница 70: ...70 ...
Страница 71: ...71 ...
Страница 72: ...72 57 C 57 C 50 C 50 C ...