– 106 –
Chapter 10 Menu Operations — Menu list
Item
Description of settings
[FORMAT MEDIA]
Formats the card in the specified slot after the format menu is selected.
[V-RAW], [MAIN SLOT1], [MAIN SLOT2], [SUB SLOT1], [SUB SLOT2], [SD CARD]
When a CPS password is set, you can select [NORMAL] (normal unencrypted format) or
[CPS(ENCRYPT)] (encrypted format).
Data deleted as a result of formatting cannot be restored. Always check the data before formatting.
[V-RAW] is displayed only when the V-RAW recorder is connected.
[MEDIA END ALARM]
Sets whether to generate an alarm sound when there is no remaining free space in the expressP2 memory
card or the microP2 memory card.
[ON], [OFF]
f
Factory setting: [ON]
[POWER
MANAGEMENT]
[DC IN SOURCE]
Sets the type of the external power supply input into the <DC IN> terminal.
[DC POWER SUPPLY]:
Selected when connecting an AC adaptor. In this case, the remaining battery
charge level is not displayed.
[BATTERY]:
Selected when connecting a battery to the <DC IN> terminal. Remaining charge level is
detected from the voltage level.
f
Factory setting: [DC POWER SUPPLY]
[DC IN BATTERY
SETTINGS]
(Display only)
[- FULL VOLT]
Sets the voltage to be displayed in the remaining charge level full display when an external battery is input
from the <DC IN> terminal.
[13.0V] - [17.0V]
(0.1 V step)
f
Factory setting: [15.5V]
[- NEAR END VOLT]
Sets the remaining charge level near end voltage when an external battery is input from the <DC IN>
terminal.
[11.0V] - [15.0V]
(0.1 V step)
f
Factory setting: [13.2V]
[- END VOLT]
Sets the remaining charge level end voltage when an external battery is input from the <DC IN> terminal.
[11.0V] - [15.0V]
(0.1 V step)
f
Factory setting: [12.5V]
[ONBORD BATTERY
SETTINGS]
(Display only)
[- BATTERY SELECT]
Selected according to the battery used.
[DIONIC], [HyTRON], [ENDURA], [PAG]:
The remaining charge level is detected and a warning is
displayed according to the [NEAR END Info] and [END Info] settings. When there is no remaining charge
level information, the remaining charge level is detected from the voltage level.
[other]:
Remaining charge level is detected from the voltage level.
f
Factory setting: [DIONIC]
[- FULL VOLT]
Sets the voltage in the remaining charge level full display when the battery remaining charge level is
detected from the voltage level.
[13.0V] - [17.0V]
(0.1 V step)
f
Factory setting: [15.5V]
[- NEAR END VOLT]
Sets the remaining charge level near end voltage when the battery remaining charge level is detected from
the voltage level.
[11.0V] - [15.0V]
(0.1 V step)
f
Factory setting: [13.2V]
[- END VOLT]
Sets the remaining charge level end voltage when the battery remaining charge level is detected from the
voltage level.
[11.0V] - [15.0V]
(0.1 V step)
f
Factory setting: [12.5V]
[- NEAR END INFO]
Sets the percentage value of the remaining charge level near end when remaining charge level information
is acquired from the battery.
[4%], [5%], [6%], [7%], [8%], [9%], [10%], [12%], [14%], [16%], [18%], [20%]
f
Factory setting: [5%]
[- END INFO]
Sets the percentage value of the remaining charge level end when remaining charge level information is
acquired from the battery.
[1%] - [10%]
(1% step)
f
Factory setting: [1%]
[EXT-REC DC IN
SOURCE]
Sets the type of the external power supply connected to the DC input terminal of the V-RAW recorder when
V-RAW shooting is performed connected to the V-RAW recorder.
Displayed only when the V-RAW recorder is connected.
[DC POWER SUPPLY]:
Select when connecting the AC adaptor. The remaining battery charge level is not
displayed in this case.
[BATTERY]:
Select when connecting a battery to the DC input terminal. The remaining battery level of the
V-RAW recorder is detected in accordance with [EXT-REC BATT FULL], [EXT-REC BATT NEAR END],
and [EXT-REC BATT END].
f
Factory setting: [DC POWER SUPPLY]
[EXT-REC BATTERY
SETTINGS]
(Display only)
[- FULL VOLT]
Sets the voltage to fully charge when the remaining charge of the battery for the V-RAW recorder is
detected with the voltage level.
Displayed only when the V-RAW recorder is connected.
[13.0V] - [17.0V]
(0.1 V step)
f
Factory setting: [15.5V]
Содержание Varicam 35
Страница 1: ...35 Operating Guide Version 6 W1014HM6056 YI VQT5K88A 6 E ...
Страница 5: ...Before using the camera read this chapter Chapter 1 Overview ...
Страница 59: ... 59 Chapter 5 Control Panel VIEW screen VIEW screen Displays video For status display contents configure MENU ...
Страница 66: ...This chapter describes the viewfinder screen display and how to make adjustments Chapter 7 Viewfinder ...
Страница 73: ...This chapter describes video output Chapter 8 Output and Screen Display ...
Страница 90: ...This chapter describes other useful features such as function buttons etc Chapter 9 Other Useful Functions ...
Страница 133: ...This chapter describes how to use the camera by connecting to network Chapter 11 Network Connection ...
Страница 153: ...This chapter describes how to use the camera by connecting to the Codex V RAW recorder Chapter 13 V RAW recorder ...
Страница 162: ...Maintenance and warning system of the camera are described Chapter 14 Maintenance ...
Страница 168: ...This chapter describes the specifications of this product Chapter 15 Specification ...
Страница 174: ...Web Site http www panasonic com Panasonic Corporation 2014 ...