95
Options Adjustments
RS-232C/LAN information timing
Set up the informing manner for no signal or temperature rising.
While RS-232C controls: Warning or error message sent on the display automatically.
While LAN controls: Acquire the warning or error message from the display.
select
adjust
RS-232C/LAN information timing
No signal warning
No signal warning timing
5min
On
10min
On
No signal error
No signal error timing
Temperature warning
On
■
No signal warning
If set to “On”, the display sends out the no signal warning.
■
No signal warning timing
Set up the detecting time for no signal warning.
(Range: 01 - 60, Interval: 1 minute)
■
No signal error
If set to “On”, the display sends out the no signal error.
■
No signal error timing
Set up the detecting time for no signal error.
(Range: 01 - 90, Interval: 1 minute)
The warning of “No signal warning” and the error of “No signal error” are not sent when the no signal state is
detected through any of the following functions:
No Signal power off: Enable, PC power management, DVI-D power management, HDMI1 power management,
HDMI2 power management (see page 78)
Setting Example
No signal warning timing: 5 minutes
No signal error timing: 10 minutes
PC power management: On (60 seconds)
If there is no signal when PC IN is input, “PC power management” is activated first and the Display enters the
standby mode.
Note:
The “No signal error timing” cannot be set shorter than “No signal warning timing”.
■
Temperature warning
If set to “On”, the display sends out the warning temperature.