68
■
Matrix Alarm Interface
The Matrix Alarm Interface is a scalable distributed digital input/output unit. Alarm input/output ports, each with a specific
functions, control the alarm processes. The basic input/output element (MXALM) has a maximum capacity of 512 digital inputs
or 512 digital outputs. Capacity can be expanded up to 1 024 inputs/outputs by combining two units.
The MXALM is composed of the following individual functional modules:
• Card cage
WJ-SX850
• 32ch Alarm Input Board
WJ-PB85A32
• 32ch Alarm Output Board
WJ-PB85L32
●
Application
An MXALM fully equipped for 512 inputs or outputs contains the following:
Description
Model No.
Qty.
Card Cage
WJ-SX850
1
32ch Alarm Input Board
WJ-PB85A32
16
or
32ch Alarm Output Board
WJ-PB85L32
16
Install the Alarm Input Boards (or Alarm Output Boards) into the slots (1 to 16) in the Card Cage as shown below.
DO NOT OPEN
RISK OF ELECTRIC SHOCK.
SIGNAL
GND
SIGNAL
GND
RS-232C
CAUTION
ATTENTION
NE PAS OUVRIR
RISQUE DE CHOCS
ELECTROUES
VS / VD
IN
OUT
VD OUT
ETHERNET
AC IN
1-32
ALARM
IN
1-32
ALARM
IN
1-32
ALARM
IN
1-32
ALARM
IN
1-32
ALARM
IN
1-32
ALARM
IN
1-32
ALARM
IN
1-32
ALARM
IN
1-32
ALARM
IN
1-32
ALARM
IN
1-32
ALARM
IN
1-32
ALARM
IN
1-32
ALARM
IN
1-32
ALARM
IN
1-32
ALARM
IN
1-32
ALARM
IN
[Board setting]
• Set switches (SW1 and SW2) on the WJ-PB85A32 Alarm Input Boards or the WJ-PB85L32 Alarm Output Boards to desig-
nate the board numbers as shown in the following table.
Slot
No.
Alarm In/Out
SW Positions
SW2
SW1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Board
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
1 - 32
33 - 64
65 - 96
97 - 128
129 - 160
161 - 192
193 - 224
225 - 256
257 - 288
289 - 320
321 - 352
353 - 384
385 - 416
417 - 448
449 - 480
481 - 512
For other DIP switch settings, refer to the Board
Setting of the individual board.
Содержание System 850
Страница 8: ...9 DETAILED PRODUCT DESCRIPTION ...
Страница 55: ...57 INSTALLATIONS AND SYSTEM CONNECTIONS ...
Страница 73: ...77 OPERATING PROCEDURES with WV CU850 ...
Страница 94: ...99 OPERATING PROCEDURES whenaWV CU350isconnected ...
Страница 114: ...119 SPECIFICATIONS ...