11
"
7HENANOBSTRUCTIONISPRESENTONTHEAIROUTLETSIDE
●
When the upward area is open
(1)
One outdoor unit installed individually
(2)
Two or more units installed side by side
*
a
a
500 mm or more
a
c
b
a
1,000 mm or more
b
250 mm or more
c
250 mm or more
*
When also using the air-discharge chamber, provide a space of
500 mm or more.
●
When an obstruction is present also in the upward area
(1)
One outdoor unit installed individually
(2)
Two or more units installed side by side
a
c
b
a
500 mm or more
b
500 mm or less
c
300 mm or more
a
c
b
e
d
a
500 mm or more
b
250 mm or more
c
250 mm or more
d
500 mm or less
e
1,000 mm or more
(C)
When an obstruction is present on both the air inlet and air outlet sides
#ASE
7HENANOBSTRUCTIONONTHEAIROUTLETSIDEISHIGHERTHANTHEO
UTDOORUNIT,(
(There is no height restriction on the air inlet side.)
●
When the upward area is open
(1)
One outdoor unit installed individually
(2)
Two or more units installed side by side
*
a
b
H
L
a
50 mm or more
b
500 mm or more
a
b
d
c
H
L
a
200 mm or more
b
1,000 mm or more
c
250 mm or more
d
250 mm or more
*
When using the air-discharge chamber, provide a space of 300 mm
or more.
●
W
HENANOBSTRUCTIONISPRESENTALSOINTHEUPWARDAREA$ONOTU
SETHEAIRDISCHARGECHAMBER
(1)
One outdoor unit installed individually
a
A
c
L
H
b
a
200 mm or more
b
500 mm or less
c
1,000 mm or more
4HEDIMENSIONALRELATIONSHIPBETWEEN(!AND,ISAS
shown in the following table.
Unit: mm
,
A
,
(
,
(
300
(,
(
500
(,
)NSTALLTHEFRAMETOACHIEVE,
(
Close the area under the frame so that the outlet air does
not bypass there.
12
(2)
Only two outdoor units installed side by side
b
a
A
c
L
H
a
200 mm or more
b
500 mm or less
c
1,000 mm or more
4HEDIMENSIONALRELATIONSHIPBETWEEN(!AND,ISAS
shown in the following table.
Unit: mm
,
A
,
(
,
(
500
(,
(
750
(,
)NSTALLTHEFRAMETOACHIEVE,
(
Close the area under the frame so that the outlet air does
not bypass there.
Only two outdoor units can be installed side by side.
#ASE
7HENANOBSTRUCTIONONTHEAIROUTLETSIDEISLOWERTHANTHEOU
TDOORUNIT,
(
(There is no height restriction on the air inlet side.)
●
When the upward area is open
(1)
One outdoor unit installed individually
(2)
Two or more units installed side by side
a
b
L
H
*
a
100 mm or more
b
500 mm or more
d
c
a
b
L
H
a
200 mm or more
b
500 mm or more
c
250 mm or more
d
250 mm or more
*
When using the air-discharge chamber, provide a space of
300 mm or more.
●
W
HENANOBSTRUCTIONISPRESENTALSOINTHEUPWARDAREA$ONOTU
SETHEAIRDISCHARGECHAMBER
(1)
One outdoor unit installed individually
A
a
H
L
c
b
a
500 mm or more
b
500 mm or less
c
1,000 mm or more
4HEDIMENSIONALRELATIONSHIPBETWEEN(!AND,ISAS
shown in the following table.
Unit: mm
A
,
(
100
(,
)NSTALLTHEFRAMETOACHIEVE,
(
Close the area under the frame so that the outlet air does
not bypass there.
(2)
Only two outdoor units installed side by side
A
a
H
L
c
b
a
1,000 mm or more
b
500 mm or less
c
1,000 mm or more
4HEDIMENSIONALRELATIONSHIPBETWEEN(!AND,ISAS
shown in the following table.
Unit: mm
A
,
(
200
(,
)NSTALLTHEFRAMETOACHIEVE,
(
Close the area under the frame so that the outlet air does
not bypass there.
Only two outdoor units can be installed side by side.
8
00_2WAY_All_282008.indb 8
00_2WAY_All_282008.indb 8
2016/12/1 9:55:11
2016/12/1 9:55:11