8
8
Control of 2WAY SYSTEM
2. Wireless Remote Controller
Matching up Addresses
Setting Remote Controller Addresses
1. If you press
and
at the same time
, “
”
will blink.
2. While holding
down, every time you press
, it cycles from ALL
1
2
3…
Set it to the receiver address switch of the indoor unit you wish to operate.
3. When you release
,
the address that was displayed is set.
When you do this, if it corresponds to the receiver’s address setting, the buzzer sounds.
6
ALL.
Address
Display on the
Remote Controller
CZ-RWSC3
Position of
the Receiver’s
Address Switch
The position of the
receiver’s address
switch does not
matter.
For 1, 2 and 3, set the switch on the
left and for 4, 5 and 6, to the right.
•
Please do not hold the [Emergency Operation]
button of the indoor unit down while the indoor unit’s display lamps are
blinking one after another.
•
Make sure to operate while the indoor unit is stopped.
•
The address of indoor unit is set to "ALL" at the time of the shipment.
NOTE
Control of 2WAY SYSTEM
2. Wireless Remote Controller
Use [Emergency Operation]
in the following situations when there is an urgent need.
When the remote controller’s batteries have failed.
When the remote controller is broken.
When the remote controller is lost.
CZ-RWSC3
Start : press [Emergency Operation] of the receiver.
If the indoor temperature is 24 °C or greater when the unit starts running, it will act as a cooler.
If the indoor temperature is less than 24 °C when the unit starts running, it will act as a heater.
Stop : press [Emergency Operation] of the receiver again.
8-11. Emergency Operation
Start/Stop
CZ-RWSC3
8-10
SM830252-00_欧州_Single_天埋.indb 10
16/08/29 13:04:37
Содержание S-200PE2E5
Страница 70: ...1 64 MEMO SM830252 00_欧州_Single_天埋 indb 64 16 08 26 10 40 29 ...
Страница 86: ... MEMO 3 4 SM830252 00_欧州_Single_天埋 indb 4 16 08 08 13 11 45 ...
Страница 166: ... MEMO 7 16 SM830252 00_欧州_Single_天埋 indb 16 16 08 27 8 24 20 ...
Страница 188: ...201608 SM830252 00_欧州_Single_天埋 indb 1 16 08 10 15 45 43 ...