Chapter 7
Appendix — Technical information
240 - ENGLISH
r
POWER
Performance
Parameter
Default value
Standby
0-63
128
No operation
64-191
Power on
192-255
r
SHUTTER
Performance
Parameter
Default value
SHUTTER: Open
0-63
128
No operation
64-191
SHUTTER: Closed
192-255
r
FADE-IN, FADE-OUT
Operate together with SHUTTER.
Performance
Parameter
Default value
OFF
0-15
255
0.5s
16-31
1.0s
32-47
1.5s
48-63
2.0s
64-79
2.5s
80-95
3.0s
96-111
3.5s
112-127
4.0s
128-143
5.0s
144-159
7.0s
160-175
10.0s
176-191
No operation
192-255
r
GEOMETRY
Performance
Parameter
Default value
OFF
0-15
255
KEYSTONE
16-31
CURVED CORRECTION
32-47
PC-1
48-63
PC-2
64-79
PC-3
80-95
CORNER CORRECTION
96-111
No operation
112-255
r
CUSTOM MASKING
To use PC-1, PC-2, or PC-3, the optional Upgrade Kit (Model No.: ET-UK20) is required.
Performance
Parameter
Default value
OFF
0-31
255
PC-1
32-63
PC-2
64-95
PC-3
96-127
No operation
128-255