Chapter 4
Settings — [DISPLAY OPTION] menu
142 - ENGLISH
f
The waveform monitor turns off when [MULTI DISPLAY] is executed during waveform monitoring.
f
The waveform monitor is not displayed when on-screen display is hidden (off).
Adjusting the waveform
Project the luminance adjustment signal of a commercial test disk (0 % (0 IRE or 7.5 IRE) – 100 % (100 IRE)) and
adjust.
Signal level
Image displayable area
Image position
1) Select “Select line (luminance)” on the waveform monitor.
2) Adjust black level.
f
Adjust the black level 0 % of the video signal to the 0 % position of the waveform monitor using the
[PICTURE] menu
→
[BRIGHTNESS].
3) Adjust white level.
f
Adjust the white level 100 % of the video signal to the 100 % position of the waveform monitor using the
[PICTURE] menu
→
[CONTRAST].
Adjusting red, green, and blue
1) Set [COLOR TEMPERATURE] to [USER1] or [USER2] (
2) Select “Select line (red)” on the waveform monitor.
3) Adjust dark red areas.
f
Use [RED] in [WHITE BALANCE LOW] to adjust the black level 0 % of the video signal to the 0 % position
of the waveform monitor.
4) Adjust bright red areas.
f
Use [RED] in [WHITE BALANCE HIGH] to adjust the white level 100 % of the video signal to the 100 %
position of the waveform monitor.
5) Use the procedure for [RED] to adjust [GREEN] and [BLUE].
Note
f
Confirm that the [SIGNAL LEVEL] setting of the input signal is correct before adjusting the black level.
Check the [SIGNAL LEVEL] setting in following menu in accordance with the input.
g
The [DISPLAY OPTION] menu
→
[SDI IN]
→
[SINGLE LINK SETTING]/[DUAL LINK SETTING]/[QUAD LINK SETTING]
→
[SIGNAL
LEVEL]
g
The [DISPLAY OPTION] menu
→
[DIGITAL LINK IN]
→
[SIGNAL LEVEL]
g
The [DISPLAY OPTION] menu
→
[SLOT IN]
→
[SINGLE LINK SETTING]/[DUAL LINK SETTING]/[QUAD LINK SETTING]
→
[SIGNAL
LEVEL]