Chapter 6
Maintenance — [SELF TEST] indications
ENGLISH - 211
[SELF TEST] indications
[SELF TEST] can be checked in the [PROJECTOR SETUP] menu
→
[STATUS]
→
[SELF TEST].
The following list shows the alphanumeric symbol that is displayed when an error or a warning has occurred and
its details. Confirm “Action number”, and follow the measure in “Measure for error and warning” (
x
page 212).
The input supply voltage is displayed only with the numeric value.
Error/warning display
Details
Action number
F015
Luminance sensor error
5
F016
Angle sensor error
5
F018
Air pressure sensor error
5
F061
Light source 1 driver communication error
5
F062
Light source 2 driver communication error
5
F090
Wave plate error
5
F096
Lens mounter operation error
5
F111
Phosphor wheel error
5
F200
LCD panel red fan warning
5
F201
LCD panel green fan warning
5
F202
LCD panel blue fan warning
5
F203
PBS fan warning
5
F204
Radiator fan 1 warning
5
F205
Radiator fan 2 warning
5
F206
Phosphor fan warning
5
F207
Power source intake fan warning
4
F208
Power source exhaust 1 fan warning
4
F209
Power source exhaust 2 fan warning
4
F250
Liquid cooling pump warning
5
F300
LCD panel red fan error
5
F301
LCD panel green fan error
5
F302
LCD panel blue fan error
5
F303
PBS fan error
5
F304
Radiator fan 1 error
5
F305
Radiator fan 2 error
5
F306
Phosphor fan error
5
F307
Power supply intake fan error
5
F308
Power supply exhaust 1 fan error
5
F309
Power supply exhaust 2 fan error
5
F350
Liquid cooling pump error
5
F400
Light source 1 unit error
5
F401
Light source 2 unit error
5
F450
Light source 1 unit error
5
F451
Light source 2 unit error
5
F500
Light source 1 error
5
F501
Light source 2 error
5
H001
Battery replacement for the internal clock
4
H011
Intake air temperature sensor error
5
H012
Exhaust air temperature sensor error
5
H014
Light source temperature sensor 1 error
5
H015
Light source temperature sensor 2 error
5
H030
Lens temperature sensor error
5
H040
Clog sensor error
5
U081
Low AC power supply voltage warning (below 90 V)
3
U084
<DC OUT> terminal power supply error
6
U090
Lens not attached error
8
U200
Intake temperature warning
1
U201
Exhaust air temperature warning
2
U203
Light source 1 temperature warning
1
U204
Light source 2 temperature warning
1
U253
Power supply temperature warning
1
Содержание PT-MZ16K
Страница 34: ...52 ENGLISH Chapter 3 Basic Operations This chapter describes basic operations to start with...
Страница 141: ...ENGLISH 159 Chapter 5 Operations This chapter describes how to use each function...
Страница 195: ...ENGLISH 213 Chapter 7 Appendix This chapter describes specifications and after sales service for the projector...