45
4.5.3.c.
Enable/Disable Individual Trap Menu
PN28168 Local Management System
SNMP Trap Receiver Configuration -> Enable/Disable Individual Trap Menu
SNMP Authentication Failure : Disabled
Enable Link Up/Down Port: 1-18
PoE Trap Control: Enabled
Temperature Trap Control: Disabled
Temperature Threshold: 65 degree(s) Celsius
FAN Failure: Enabled
-------------------------------- <COMMAND> -----------------------------------
Enable/Disable [A]uth Fail Trap
Add Link Up/Down Trap [P]orts
[D]elete Link Up/Down Trap Ports
Enable/Disable Po[E] Trap
Enable/Disable [T]emperature Trap
[S]et Temperature Threshold
Enable/Disable [F]AN Fail Trap
[Q]uit to previous menu
Command>
Enter the character in square brackets to select option
On the SNMP Trap Receiver Configuration Menu, pressing "D" opens the Enable/
Disable Individual Trap Menu screen, as shown in Fig. 4-13. On this screen, you can set
the trap sending settings.
Fig. 4-13 Enable/Disable Individual Trap