21
PAW-VP•LDHW - Technical Manual – 2019-11
Technical Data of Indoor Unit
1
1.1.3 Tank model PAW-VP1000/750LDHW
Heat Pump Model
U-16MF3E8
U-16MF3E8
Tank Model
PAW-VP1000LDHW PAW-VP750LDHW
Volume L
933
726
Height×Diameter mm
2210x990
1855x990
Connections to the water supply network
RP 1 1/4”
RP 1 1/4”
Net weight / with water
kg
191 / 1121
179 / 929
Heat Pump
Nominal electrical power
kW
6.14
5.12
Reference tapping cycle
2XL
2XL
Energy consumption by chosen cycle A7/W10-55
kWh
5.1
4.14
Energy consumption by chosen cycle A14/W10-55
kWh
4.61
3.5
COP DHW (A7/W10-55) EN16147
4.81
5.29
COP DHW (A14/W10-55) EN16147
5.32
7.01
Energy Effiency Class
for Energy Label; (EU) No. 812/2013 ANNEX
III
(A+–F)
Not in the Scope of the regulation
for Product fiche: (EU) No. 812/2013 ANNEX
II
, Table1
Standby heat loss
W/h
80
77
Sound power/Sound pressure (Outdoor/evaporator unit)
dB/dB(A)
57/52
57/52
Refrigerant
R410A
R410A
Refrigerant at shipment
kg
8.3
8.3
Outdoor ambient operating range
°C
-20/+35
-20/+35
Heating up time
min
162
133
VP tank DHW
Stainless steel 316L pickling/protective magnesium anode
+/+
+/+
Average insulation thickness
mm
100
100
Internal exchanger (m² surface~connection)
4.0~1/2"–3/4"
4.0~1/2"–3/4"
Electrical specifications
Max power consumption without heater /with heater
kWh
20.4/26.4
20.4/26.4
Number of electrical heaters x power
W
1×6000
1×6000
Voltage / frequency
V/Hz
400/50
400/50
Electric protection heat pump /heaters
A
40/16
40/16
Moisture protection
IP24
IP24
Working pressure (storage tank / heat exchanger)
MPa(bar)
0.95(9.5)/5.5(55)
0.95(9.5)/5.5(55)
Domestic hot water preparation
Preparation with heat pump Min/Max water temperature
°C
5/65
5/65
Preparation with electrical heater Min/Max water temperature
°C
15/85
15/85
Refrigerant information
Refrigerant (R410A)
kg/TCO2 Eq
8.3/17.1
8.3/17.1
Refrigerant (R32)
kg/TCO2 Eq
—
—
- EN 16147:2017 - Heat pumps with electrically driven compressors.
Testing and requirements for making of domestic hot water units;
- Commission Delegated Regulation (EU) No. 812/2013 and Commission Regulation (EU) No. 814/2013.
Содержание PAW-VP1000LDHW
Страница 2: ......
Страница 122: ...122 PAW VP LDHW Technical Manual 2019 11 Appendix A A 2 Spare parts Tanks ...
Страница 123: ...123 PAW VP LDHW Technical Manual 2019 11 Appendix A ...
Страница 124: ...124 PAW VP LDHW Technical Manual 2019 11 Appendix A ...
Страница 125: ...125 PAW VP LDHW Technical Manual 2019 11 Appendix A ...
Страница 126: ...126 PAW VP LDHW Technical Manual 2019 11 Appendix A ...
Страница 132: ......
Страница 133: ......
Страница 134: ...Polar Energi AS Postboks 117 9450 Hamnvik Norway www polarenergi com ...