80
7.1
Communication
Term
Command
Description (*)=Default
Baud rate
BAUD=aaaa
Baud rate of RS-232C
aaaa=1200; 1200bps,
aaaa=2400; 2400bps,
aaaa=4800; 4800bps,
aaaa=9600; 9600bps,
(*),
aaaa=19200; 19200bps,
aaaa=38400; 38400bps,
aaaa=57600; 57600bps,
aaaa=115200; 115200bps,
Frame
FRAME=0
7 bits, Odd, Stop bit 1
FRAME=1
7 bits, Odd, Stop bit 2
FRAME=2
7 bits, Even, Stop bit 1
FRAME=3
7 bits, Even, Stop bit 2
FRAME=4
8 bits, None, Stop bit 1 (*)
FRAME=5
8 bits, None, Stop bit 2
FRAME=6
8 bits, Odd, Stop bit 1
FRAME=7
8 bits, Odd, Stop bit 2
FRAME=8
8 bits, Even, Stop bit 1
FRAME=9
8 bits, Even, Stop bit 2
Header
HEAD=a
Header character
a=0; None (*)
a=1; [SX]
a=2; [EC]
Terminator
TERM=a
Terminator character
a=0; None
a=1; [EX]
a=2; [EX][CR]
a=3; [CR][LF]
(*)
a=4; [CR]
a=5; [CR][TAB]
a=6; [TAB][CR]
Command
CMDFORM=0
[CR] or [CR][LF]
(*)
Format
CMDFORM=1
[[Terminator]
Separator
SEPA=a
Character code
a=0; None
a=1; &
a=2; ,
(Comma) (*)
a=3; [FS] (1C hex)
a=4; [GS] (1D hex)
a=5; [SP] (20 hex)
Prefix
PREFIX=a
Prefix character
=a,\bb
a=0; Disable (*)
a=1; Enable
bb; Suffix character(Hexadecimal code (*1) bb=00
(*) [NUL]
When omitting
“
bb
”, configured identifier will not changed.
Suffix
SUFFIX=a
Suffix character
=a,\bb
a=0; Disable (*)
a=1; Enable
bb; Suffix character(Hexadecimal code (*1) bb=00
(*) [NUL]
When omitting “bb”, configured identifier will not changed.
RS/CS control
RSCS=0
Disable RTS/CTS flow control (*)
RSCS=1
Enable RTS/CTS flow control
TCP/IP arrival
confirmation
TCPCS=0
Disable data arrival confirmation (*)
TCPCS=1
Enable data arrival confirmation
COM Port
(Sync
command, Data
output)
COMFROM=0
RS-232C only
(*)
COMFROM=1
LAN only
COMFROM=2
RS-232C and LAN
Control Code
LABELTX=0
Pass through
(*)
LABELTX=1
Change Control code to ASCII code within [hex].
Timeout period TXWAIT=a
Timeout period for decoded data
a=1000 to 2500 [ms]; 10[ms] step 1000[ms] (*)
(*1
) Refer to “7.16 Table of Character Code”