38
Force-quit running auto-tuning
*cancel
Auto-tuning takes a lot of time. This command is used for canceling an
auto-tuning. Code Reader force-quits the auto-tuning.
Check the condition of LP-ABR
*?state
This command is used for checking the condition of your Code Reader.
The answers from Code Reader are as follows.
Condition
Answer
Reading standby
STANDBY[CR]
Auto-tuning
RECEIVED[CR]
Waiting data save
SAVEWAIT(a)[CR]
Reading
(No answer)
†
(a) is the number of tuning results that can be saved. (a: 1 to 3)
Save Tuning Result
This command is used for saving a result of auto-tuning to the table mode.
The save destination table differs depending on the serial command.
When Code Reader receives this command within 40 seconds after the
completion of auto-tuning, the result of the tuning is saved to the table mode.
If no command is received, Code Reader times out and returns to reading
standby state.
*save
This command is used for saving results of auto-tuning to the table mode.
Save the results into Table 1 to 3.
*save2
This command is used for saving a result of auto-tuning to the manual
mode.
*save3=a,b
a: Start position (1 to 8)
b: Number of entries (1 to 3)
This command is used for saving results of auto-tuning to the table mode.
Save number of the “b” results from table “a”.