95
7.15 General Operation
Term
Command
Description (*)=Default
Initialization
SET=DFT
Reset to factory default
Save
WSETS
Save settings to internal flash memory
Buzzer
buz=a
a=0; Buzzer OFF, a=1; Buzzer ON
(*)
Digital I/O
CHATT=a
Debouncing time
a=0; None (*) a=1; 10ms a=2; 20ms
GOOUT=a
a=0; GO output is holded until next SYNC input
a=100 to 20000; GO output time [Unit: ms]
a=300 (*)
NGOUT=a
a=0; NG output is holded until next SYNC input
a=100 to 20000; NG output time [Unit: ms]
a=300 (*)
Digital I/O
signal
assignment
DOUT1=a
Assign the signal to output to DOUT1
a=0; Disable a=1; GO (Good read)
(*)
a=2; NG (No read)
a=3; Ready a=4; Busy1
DOUT2=a
Assign the signal to output to DOUT2
a=0; Disable a=1; GO(Good Read) a=2; NG(No Read) (*)
a=3; Ready a=4; Busy1
DOUT3=a
Assign the signal to output to DOUT3
a=0; Disable a=1; GO(Good Read) a=2; NG(No Read) (*)
a=3; Ready
(*)
a=4; Busy1
7.16 Table of Character Code