72
6.4
Check for LAN settings
6.4.1
Through RS-232C interface
LAN setting can be confirmed through RS-232C interface anytime.
?Confirm the LAN settings by the command below.
The following parameters are sent to the host:
-
IP address
-
Sub net mask
-
Default gateway
-
Port number of TCP server connection (only for reading result transmission)
-
Port number of TCP server connection (only for image data transmission)
-
Destination of TCP client communication (only for reading result transmission)
-
Destination of TCP client communication (only for image data transmission)
-
Connection request interval (only for TCP client communication)
-
Detection timer (only for TCP client communication)
6.4.2 Through LAN interface
Communication state can be checked by UDP (User Datagram Protocol), if the
network address is already known.
Set IP address of the host into the same network as the reader.
Connect LP-ABR series to the PC for configuration with a LAN cable.
Specify the broadcast / port number as a UDP communication destination.
†
The port number is 49460 fixed.
†
If multiple LP-ABR are connected in a same network, respective devices will
respond.
Confirm the settings by the command below.
The following parameters are output in a line:
-
Local IP address
(IP address of TFIR-31LAN)
-
Local port number (Port number of TCP/IP server of LP-ABR series)
-
Sub net mask
-
Default gateway
-
MAC address (last 3 bytes)
?who
?LAN