Environmental Requirements (KX-TVA200 only)
The hard disk drive is sensitive to cold, heat, dryness, humidity, shock, vibration, and magnetic fields. Please
observe the conditions specified below.
Hard Disk Drive Usage Environment
Operating Temperature:
5 °C to 40 °C (41 °F to 104 °F)
Operating Humidity:
See the graph below.
Shock:
Under 5 G
Vibration:
5 Hz to 22 Hz:
0.0042 cm (0.020 in.) displacement; double amplitude, 1
octave per minute.
23 Hz to 350 Hz: Under 0.5 G
Magnetic Field:
DC: 0.6 mT
to 700 kHz: 0.7 µT
700 kHz to 1.5 MHz: 3 µT
Allowable Relative Humidity vs. Temperature
0
10
20
30
40
50
60
70
80
90
100
55
15
35
45
25
5
(°C)
Relative Humidity (%)
Temperature
Operating Area
41
59
77
95
113 131 (°F)
Document Version 3.0 2010/06
Installation Manual
35
2.1 Before Installation
Содержание KX-TVA50
Страница 16: ...16 Installation Manual Document Version 3 0 2010 06 Table of Contents...
Страница 32: ...32 Installation Manual Document Version 3 0 2010 06 1 3 Specifications...
Страница 84: ...84 Installation Manual Document Version 3 0 2010 06 2 15 2 Wall Mounting the AC Adaptor...
Страница 162: ...162 Installation Manual Document Version 3 0 2010 06 5 7 KX TA Series PBX Programming for Inband Integration...
Страница 180: ...180 Installation Manual Document Version 3 0 2010 06 6 2 2 Changing the Maximum Length of Mailbox Numbers...
Страница 190: ...190 Installation Manual Document Version 3 0 2010 06 7 3 2 Button Assignment via PC Programming...
Страница 199: ...Section 9 Revision History Document Version 3 0 2010 06 Installation Manual 199...
Страница 201: ...Index Document Version 3 0 2010 06 Installation Manual 201...
Страница 206: ...206 Installation Manual Document Version 3 0 2010 06 Notes...
Страница 207: ...Document Version 3 0 2010 06 Installation Manual 207 Notes...