1.2.2 Connection Examples—KX-TVA50
DPT Integration
When using DPT Integration, VPS jacks are connected to the digital extension ports of the PBX. Note that only
odd numbered VPS jacks (1, 3, and 5) can be used. Each of these VPS jacks provides 2 VPS ports and can
handle 1 call per port.
Note
•
For DPT Integration, the lowest numbered jack of the VPS must be connected to the lowest numbered
port of the Voice Mail group assigned through PBX programming.
Connection Example (Factory-installed Jacks and KX-TVA502
´
2, DPT Integration
Mode)
PBX (KX-TDA50)
Slot 1
Port 2
Port 1
Port 4
Port 3
Port 2
Port 1
KX-TVA50
Assigned as VM (DPT) ports
Jack 1
Jack 2
Factory- installed
Jacks
Slot 3
Port 6
Port 5
Jack 5
Jack 6
KX-TVA502
Slot 2
Port 4
Port 3
Jack 3
Jack 4
KX-TVA502
DLC4 Card
01
02
03
01
02
03
Jack 6
Jack 5
Jack 2
Jack 1
Jack 4
Jack 3
Document Version 3.0 2010/06
Installation Manual
25
1.2.2 Connection Examples—KX-TVA50
Содержание KX-TVA50
Страница 16: ...16 Installation Manual Document Version 3 0 2010 06 Table of Contents...
Страница 32: ...32 Installation Manual Document Version 3 0 2010 06 1 3 Specifications...
Страница 84: ...84 Installation Manual Document Version 3 0 2010 06 2 15 2 Wall Mounting the AC Adaptor...
Страница 162: ...162 Installation Manual Document Version 3 0 2010 06 5 7 KX TA Series PBX Programming for Inband Integration...
Страница 180: ...180 Installation Manual Document Version 3 0 2010 06 6 2 2 Changing the Maximum Length of Mailbox Numbers...
Страница 190: ...190 Installation Manual Document Version 3 0 2010 06 7 3 2 Button Assignment via PC Programming...
Страница 199: ...Section 9 Revision History Document Version 3 0 2010 06 Installation Manual 199...
Страница 201: ...Index Document Version 3 0 2010 06 Installation Manual 201...
Страница 206: ...206 Installation Manual Document Version 3 0 2010 06 Notes...
Страница 207: ...Document Version 3 0 2010 06 Installation Manual 207 Notes...