Troubleshooting
312
Installation Manual
(28) Digital trunk failure (DSP link failure)
Error Code
1328 xyy: DSP-1 link failure
x = 1 to 3: Shelf number
yy = 01 to 14: Slot number
Possible cause of
the malfunction
1.
DSP (Digital Signal Processor) link failure of T1 card occurred.
Countermeasures
Note
Another T1 card with next priority will work as a master card, if more
than two T1 cards are registered to the system by PC programming
(TSW card configuration) beforehand. Otherwise, the system will
synchronize with the system internal clock.
Confirm that the setting of "Frame Sequence" and
"Line Coding" are matched with that of the leased
lines. If not, change the setting of your KX-TD500 and
CSU. Then check the clock mode.
Ask the T1 carrier to check the line conditions.
Or check the equipment in other switching system which
your T1 lines are connected with.
Check the CSU. If not good, replace it with a new one.
End
OK
OK
OK
NG
OK
Test Results NG
Test Results OK
NG
NG
Replace the T1 card with a new
one.
Check the cabling between "T1 and CSU" and "CSU
and NIU." If not properly cabled, change the cabling.
Execute Loop Back Test (Internal).
Execute Loop Back Test (External : between KX-
TD500 and CSU).
NG
Содержание KX-TD500
Страница 18: ...Table of Contents 18 Installation Manual ...
Страница 54: ...System Outline 54 Installation Manual ...
Страница 156: ...Installation 156 Installation Manual Note Four CO lines are available for the Caller ID service with one Caller ID card ...
Страница 178: ...Installation 178 Installation Manual ...
Страница 182: ...Maintenance Console Guide 182 Installation Manual 4 Click if you accept License Agreement ...
Страница 208: ...Maintenance Console Guide 208 Installation Manual ...
Страница 271: ...Utility Installation Manual 271 4 Click Capture off The system creates a Log File ...
Страница 272: ...Utility 272 Installation Manual ...