5.2.3
Troubleshooting via Error Log Records
Error
code
Sub
code
Severity
AUTOMATIC FAULT
REPORT (SMDR)
MESSAGE (MAX. 39
characters)
LOCAL ALARM
MESSAGE
COMMENTS
PT (Max.16 digits)
1000
mm
MJ
-
-
Hard WDT
overflow
1001
mm
MJ
-
-
Illegal interrupt
1002
mm
MJ
-
-
Soft WDT
overflow
1100
MJ
TSW clock down
ERR
TSW
DWN
1101
MJ
-
-
Basic shelf DC
power down
1102
MJ
Expansion shelf 1 DC
power down
ERR
DC
DOWN
1103
MJ
Expansion shelf 2 DC
power down
ERR
DC
DOWN
1104
MJ
Basic shelf heat alarm
B/S
OVER
HEAT!
1105
MJ
Expansion shelf 1 heat
alarm
E/S1
OVER
HEAT!
1106
MJ
Expansion shelf 2 heat
alarm
E/S2
OVER
HEAT!
1107
MJ
Basic shelf fan alarm
B/S
FAN
FLT!
1108
MJ
Expansion shelf 1 fan alarm E/S1
FAN
FLT!
1109
MJ
Expansion shelf 2 fan alarm E/S2
FAN
FLT!
1110
MJ
Calendar IC R/W stop
ERR
CLCK
IC
1111
MJ
Calendar IC stop
ERR
CLCK
IC
1112
MJ
CPU RAM battery alarm
ERR
BAT
ALM
1200
MN
Basic shelf AC power down ERR
AC
DOWN
1201
MN
Expansion shelf 1 AC
power down
ERR
AC
DOWN
1202
MN
Expansion shelf 2 AC
power down
ERR
AC
DOWN
1203
MN
-
ERR
SMDR
SMDR
Not Connect
1300
xyy
MN
Echo back error
-
Содержание KX-TD500
Страница 18: ...Table of Contents 18 Installation Manual ...
Страница 54: ...System Outline 54 Installation Manual ...
Страница 156: ...Installation 156 Installation Manual Note Four CO lines are available for the Caller ID service with one Caller ID card ...
Страница 178: ...Installation 178 Installation Manual ...
Страница 182: ...Maintenance Console Guide 182 Installation Manual 4 Click if you accept License Agreement ...
Страница 208: ...Maintenance Console Guide 208 Installation Manual ...
Страница 271: ...Utility Installation Manual 271 4 Click Capture off The system creates a Log File ...
Страница 272: ...Utility 272 Installation Manual ...