Utility
230
Installation Manual
Notes
•
This test applies to all DPTs and a certain type of APT (KX-T7130 only). If other type
of PTs are used for the test, the message "Not Available" will be displayed.
•
When executing this test with KX-T7130, use a 6-conductor wiring cord (3-paired wire)
for testing the OHCA path.
•
When executing this test, a PT in "INS (In-Service)" status should be connected to the
specified card. Otherwise the test is not available.
•
A message "PT Link failure" will also be displayed, if the test target is an SLT card.
•
If both messages "PT Normal Path failure" and "PT OHCA Path failure" are displayed
simultaneously, there will be a possibility of PT PB Generator failure.
[Card/Port Test] PT Path Test - Error Indication Table
Error Message
Description
Card
Applied
PT Link failure
Communication link between the target card and
PT is abnormal.
PLC, HLC,
DLC, DHLC
PT Normal Path
failure
PT Normal Path is not functioning properly.
PLC, HLC,
DLC, DHLC
PT OHCA Path
failure
PT OHCA Path is not functioning properly.
PLC, HLC,
DLC, DHLC
Not Available
The PT connected to the specified port is not
applicable to this test.
APTs other than KX-T7130 are not applicable to
this test.
PLC, HLC,
DHLC
Содержание KX-TD500
Страница 18: ...Table of Contents 18 Installation Manual ...
Страница 54: ...System Outline 54 Installation Manual ...
Страница 156: ...Installation 156 Installation Manual Note Four CO lines are available for the Caller ID service with one Caller ID card ...
Страница 178: ...Installation 178 Installation Manual ...
Страница 182: ...Maintenance Console Guide 182 Installation Manual 4 Click if you accept License Agreement ...
Страница 208: ...Maintenance Console Guide 208 Installation Manual ...
Страница 271: ...Utility Installation Manual 271 4 Click Capture off The system creates a Log File ...
Страница 272: ...Utility 272 Installation Manual ...