Troubleshooting
Installation Manual
311
(27) Digital trunk failure (error rate over)
Error Code
1325 xyy: Digital trunk error rate over
x = 1 to 3: Shelf number
yy = 01 to 14: Slot number
Possible cause of
the malfunction
1.
The PBX exceeded the number of multiframe errors per second
which the PBX required to recognize the remote alarm.
Countermeasures
Note
Another T1/PRI23 card with next priority will work as a master card, if
more than two T1/PRI23 cards are registered to the system by PC
programming (TSW card configuration) beforehand. Otherwise, the
system will synchronize with the system internal clock.
Confirm that the setting of "Frame Sequence" and
"Line Coding" are matched with that of the leased
lines. If not, change the setting of your KX-TD500 and
CSU. Then check the clock mode.
Ask the T1/PRI23 carrier to check the line conditions.
Or check the equipment in other switching system
which your T1/PRI23 lines are connected with.
Check the CSU. If not good, replace it with a new one.
Try Loop Back Test again.
End
OK
OK
OK
NG
OK
Test Results NG
Test Results OK
NG
NG
Check the cabling between "T1/PRI23 and CSU"
and "CSU and NIU." If not properly cabled, change the
cabling.
Execute Loop Back Test (Internal).
Execute Loop Back Test (External : between KX-TD500
and CSU).
NG
Replace the T1/PRI23 card with
a new one.
Содержание KX-TD500
Страница 18: ...Table of Contents 18 Installation Manual ...
Страница 54: ...System Outline 54 Installation Manual ...
Страница 156: ...Installation 156 Installation Manual Note Four CO lines are available for the Caller ID service with one Caller ID card ...
Страница 178: ...Installation 178 Installation Manual ...
Страница 182: ...Maintenance Console Guide 182 Installation Manual 4 Click if you accept License Agreement ...
Страница 208: ...Maintenance Console Guide 208 Installation Manual ...
Страница 271: ...Utility Installation Manual 271 4 Click Capture off The system creates a Log File ...
Страница 272: ...Utility 272 Installation Manual ...