Connection between the Central Office and the system:
Troubleshooting
6-3
6.2
While Connecting
Connection between the system and a proprietary telephone:
CAUSE
SOLUTION
T/R is connected to H/L.
Use the correct cord
(the inner 2 wires are for T/R
and the outer 2 wires are for
H/L).
H •
T •
R •
L •
• H
• T
• R
• L
KX-TA308 or
KX-TA616
Extension
Connection between the system and a single line telephone:
CAUSE
SOLUTION
T/R is connected to H/L.
Use the correct cord
(the inner 2 wires are for
T/R).
H •
T •
R •
L •
•
• T
• R
•
KX-TA308 or
KX-TA616
Extension
Connection between the system and a single line telephone that is polarity-
sensitive:
CAUSE
SOLUTION
“T” is connected to “R”.
Reverse the connections of
T/R.
H •
T •
R •
L •
•
• T
• R
•
KX-TA308 or
KX-TA616
Extension
CAUSE
Outside lines are connected to H/L.
Reconnect the outside (CO)
lines to T/R using 2-conductor
wiring.
•
•
•
• T
• R
•
KX-TA308 or
KX-TA616
Outside line
Can you dial an
extension?
Can you dial
out using an
outside (CO)
line?
No
No
Yes
SOLUTION
Содержание KX-TA616
Страница 13: ...Section 1 Basic System Construction ...
Страница 16: ...1 4 Basic System Construction ...
Страница 17: ...Section 2 Installation ...
Страница 51: ...Section 3 Features ...
Страница 118: ...3 68 Features ...
Страница 119: ...Section 4 System Programming ...
Страница 200: ...4 82 System Programming ...
Страница 201: ...Section 5 Appendix ...
Страница 209: ...Section 6 TroubleShooting ...
Страница 213: ...Section 7 Programming Tables ...
Страница 243: ...Memo ...
Страница 244: ...Memo ...