System Programming
4-29
4.2
System Programming
[212]-[213]
Sets the maximum time between detecting one bell signal and the next from the Central
Office. In case the next bell signal is not detected within the programmed time, the system
recognizes the bell signal has stopped.
Default
6 seconds
3
1
2
[213] Bell Off Detection
NEXT
SELECT
STORE
END
(3/6/12 sec)
Sets the maximum time allowed for a conversation with an external party. This program is
effective for the extension(s) which assigned “Enable” in program [613] “Outside (CO) Line
Duration Limit Selection”.
Default
10 minutes
• A beep sounds at 5-second intervals 15 seconds before the programmed time expires.
• This program is effective only for an outgoing outside call.
• When making a call after an outside (CO) line is seized and transferred to the enabled
extension in program [613] by another extension, the timer starts after the call has been
transferred.
• Feature Reference
Section 3, Features
Limited Call Duration
2
1
2
[212] Outside (CO) Line Duration Time Limit
NEXT
STORE
END
time
(1··32 minutes)
!
!
☞
Содержание KX-TA616
Страница 13: ...Section 1 Basic System Construction ...
Страница 16: ...1 4 Basic System Construction ...
Страница 17: ...Section 2 Installation ...
Страница 51: ...Section 3 Features ...
Страница 118: ...3 68 Features ...
Страница 119: ...Section 4 System Programming ...
Страница 200: ...4 82 System Programming ...
Страница 201: ...Section 5 Appendix ...
Страница 209: ...Section 6 TroubleShooting ...
Страница 213: ...Section 7 Programming Tables ...
Страница 243: ...Memo ...
Страница 244: ...Memo ...