PROBLEM
PROBABLE CAUSE
SOLUTION
The status of the port
property of an SLT
extension is FAULT.
•
The telephone is
off-hook.
Put the telephone on-hook and restart the
PBX.
Note
This solution does not apply to the power
failure ports (ports 1, 2 on the pre-installed
MCSLC card).
•
There is a problem in
the wiring.
Disconnect all cabling between the PBX and
SLTs, and restart the PBX.
After restarting, if operation is normal, there is
probably a problem in the wiring or
connection. (For example, there might be a
short circuit in the switchboard or cabling.)
Note
This solution does not apply to the power
failure ports (ports 1, 2 on the pre-installed
MCSLC card).
•
The SLT circuitry is
damaged.
Consult a certified dealer.
Installation Manual
293
7.1.3 Operation
Содержание KX-NS500
Страница 16: ...16 Installation Manual Table of Contents ...
Страница 28: ...28 Installation Manual 1 4 Data Security ...
Страница 58: ...58 Installation Manual 2 3 3 System Capacity ...
Страница 78: ...78 Installation Manual 3 1 3 Using CTI Applications ...
Страница 114: ...4 Hook the main unit on the screw heads 114 Installation Manual 4 2 10 Wall Mounting ...
Страница 175: ...Example KX NT346 Ethernet Straight Cable To a PC Installation Manual 175 4 11 2 LAN Connections for IP Telephones ...
Страница 280: ...Example IMAP Account Settings Outlook 2010 280 Installation Manual 5 10 Programming E mail Integration for UM Voice ...
Страница 286: ...286 Installation Manual 6 1 Methods of Stacking Expansion Units ...
Страница 300: ...300 Installation Manual 7 1 6 Troubleshooting by Error Log ...
Страница 332: ...332 Installation Manual 8 6 Port Security ...
Страница 337: ...Installation Manual 337 Notes ...