PIN Assignment for Door opener Port
No.
Signal Name
Function
8
1
1
OP1a
Door opener 1 (Relay 1)
2
OP1b
Door opener 1 com (Relay 1 com)
3
Reserved
-
4
Reserved
-
5
Reserved
-
6
Reserved
-
7
OP2a
Door opener 2 (Relay 2)
8
OP2b
Door opener 2 com (Relay 2 com)
External Sensor
Power to the external sensor is provided from the DPH2 card and must be grounded through the DPH2 card
as indicated in the diagram below. A pair of "sensor" and "common" lines are connected to the DPH2 card for
each external sensor. The PBX detects input from the sensor when the signal is under 100
W
.
Connection Diagram
External Sensor
sensor
common
I/O
DOORPHONE
PBX
+3.3V
+3.3V
10K
33
33
4.7K
4.7K
Door Opener
Current Limit: 24 V DC/30 V AC, 1 A maximum
Installation Manual
161
4.7.1 DPH2 Card (KX-NS5162)
Содержание KX-NS500
Страница 16: ...16 Installation Manual Table of Contents ...
Страница 28: ...28 Installation Manual 1 4 Data Security ...
Страница 58: ...58 Installation Manual 2 3 3 System Capacity ...
Страница 78: ...78 Installation Manual 3 1 3 Using CTI Applications ...
Страница 114: ...4 Hook the main unit on the screw heads 114 Installation Manual 4 2 10 Wall Mounting ...
Страница 175: ...Example KX NT346 Ethernet Straight Cable To a PC Installation Manual 175 4 11 2 LAN Connections for IP Telephones ...
Страница 280: ...Example IMAP Account Settings Outlook 2010 280 Installation Manual 5 10 Programming E mail Integration for UM Voice ...
Страница 286: ...286 Installation Manual 6 1 Methods of Stacking Expansion Units ...
Страница 300: ...300 Installation Manual 7 1 6 Troubleshooting by Error Log ...
Страница 332: ...332 Installation Manual 8 6 Port Security ...
Страница 337: ...Installation Manual 337 Notes ...