4.3.4 LCOT6 in KX-NS500 (installed by default)
Function
•
6 analogue trunk ports with Caller ID (FSK/FSK with Call Waiting Caller ID [Visual Caller ID]/DTMF).
•
6 MOH/External Pager port.
•
2 ports are power failure transfer (PFT) ports. (Port 1 and Port 2)
Note
•
CO ports number, MOH ports number and External Pager ports number are as table below.
•
You can select port Type "CO use (default)", "MOH or External Pager use" for each port by using WEB
Maintenance Console.
•
Pair of an ODD port number and an EVEN port should be CO use or MOH/Pager use.
Example. If you select Port 5 as MOH (BGM 7), Port 6 should be MOH (Port 8) or Pager 6 as below.
To trunk
Port Type and Port Number
Port Type
Port Number
CO (Default)
Port 1 = CO 1
Port 2 = CO 2
Port 3 = CO 3
Port 4 = CO 4
Port 5 = CO 5
Port 6 = CO 6
MOH
Port 1 = BGM 3
Port 2 = BGM 4
Port 3 = BGM 5
Port 4 = BGM 6
Port 5 = BGM 7
Port 6 = BGM 8
Installation Manual
127
4.3.4 LCOT6 in KX-NS500 (installed by default)
Содержание KX-NS500
Страница 16: ...16 Installation Manual Table of Contents ...
Страница 28: ...28 Installation Manual 1 4 Data Security ...
Страница 58: ...58 Installation Manual 2 3 3 System Capacity ...
Страница 78: ...78 Installation Manual 3 1 3 Using CTI Applications ...
Страница 114: ...4 Hook the main unit on the screw heads 114 Installation Manual 4 2 10 Wall Mounting ...
Страница 175: ...Example KX NT346 Ethernet Straight Cable To a PC Installation Manual 175 4 11 2 LAN Connections for IP Telephones ...
Страница 280: ...Example IMAP Account Settings Outlook 2010 280 Installation Manual 5 10 Programming E mail Integration for UM Voice ...
Страница 286: ...286 Installation Manual 6 1 Methods of Stacking Expansion Units ...
Страница 300: ...300 Installation Manual 7 1 6 Troubleshooting by Error Log ...
Страница 332: ...332 Installation Manual 8 6 Port Security ...
Страница 337: ...Installation Manual 337 Notes ...