2.
Follow the procedure below for the KX-NS1000.
a.
Make sure the power switch is turned off.
b.
Insert a STACK-M card into the free slot.
c.
Connect the stacking cable to the STACK-M card.
3.
Follow the procedure below for the KX-NS1000 and legacy gateways.
a.
Turn the power switch on.
Procedure for Case 3
To stack PBXs to a running Master unit or Slave unit in a One-look network, follow the procedure below.
1.
Follow the procedure below for the PBXs to be connected as legacy gateways.
a.
Make sure the power switch is turned off.
b.
Remove the MPR card, and then insert a STACK-S (NCP)/STACK-S (TDE) card.
c.
Connect the stacking cable to the STACK-S (NCP)/STACK-S (TDE) card.
2.
Follow the procedure below for the KX-NS1000.
a.
Shutdown the Master unit and then turn off the power switch.
Note
The Slave units in the One-look network will reboot when the Master unit is shutdown.
b.
Connect the stacking cable to the STACK-M card.
3.
Follow the procedure below for the KX-NS1000 and legacy gateways.
a.
Turn the power switch on.
One-look network will start working normally.
Note
To programme the One-look network, refer to "5.5 Programming a One-look Network".
Procedure for Case 4
To stack PBXs with a KX-NS1000 which is running already as stand-alone, and then start One-look network,
follow the procedure below.
Notice
•
If you wish to continue to use the programmed settings (e.g., Speed Dial and Caller ID, DDI/DID Table,
etc.) of PBXs that will be connected to the KX-NS1000 as legacy gateways, export each PBX's data
before beginning the procedure for Case 4. Then, after completing the procedure for Case 4, import
the data to the Master unit of the One-look network.
For exporting data from PBXs that will be connected to the KX-NS1000 as legacy gateways, refer to
the PC Programming Manual of the corresponding PBX.
•
When importing data from other PBXs to a Master unit, make sure no extension numbers or port
numbers programmed in the import data are already in use on the Master unit.
1.
Follow the procedure below for the PBXs to be connected as legacy gateways.
a.
Make sure the power switch is turned off.
b.
Remove the MPR card, and then insert a STACK-S (NCP)/STACK-S (TDE) card.
c.
Connect the stacking cable to the STACK-S (NCP)/STACK-S (TDE) card.
2.
Follow the procedure below for the KX-NS1000.
a.
Shutdown the KX-NS1000, and then turn off the power switch.
b.
Insert a STACK-M card into the free slot.
c.
Connect the stacking cable to the STACK-M card.
3.
Follow the procedure below for the KX-NS1000 and legacy gateways.
a.
Turn the power switch on.
4.
Follow the procedure below for the KX-NS1000.
When the KX-NS1000 is going to be a Master unit.
a.
Reboot the other KX-NS1000s (Slave units).
316
Installation Manual
6.2 Methods of Stacking PBXs
Содержание KX-NS1000
Страница 40: ...40 Installation Manual 1 4 Data Security ...
Страница 76: ...76 Installation Manual 2 3 3 System Capacity ...
Страница 108: ...108 Installation Manual 3 1 3 Using CTI Applications ...
Страница 191: ...Example KX NT346 Ethernet Straight Cable To a PC Installation Manual 191 4 11 2 LAN Connections for IP Telephones ...
Страница 267: ...the priority Installation Manual 267 5 8 3 Setting LLDP Parameters ...
Страница 312: ...312 Installation Manual 5 12 Automatic Configuration of Mailboxes ...
Страница 318: ...318 Installation Manual 6 2 Methods of Stacking PBXs ...
Страница 332: ...332 Installation Manual 7 1 6 Troubleshooting by Error Log ...
Страница 400: ...400 Installation Manual 8 6 26 WAN Port Mirroring ...
Страница 414: ...414 Installation Manual 9 3 7 PCMPR Software File Version 004 1xxxx ...