LED Indications
Indication
Colour
Description
STATUS
Green
PBX status indication
•
OFF: Power Off
•
ON: Power On and running
•
Flashing: Starting up/Logging in
Amber
PBX status indication
•
ON: Ready to shutdown
•
Flashing: Shutting down
Red
PBX status indication
•
ON: Alarm
The cause may be one of the following:
–
Power was cut without performing the
shutdown procedure.
–
No IP address(es) assigned for the DSP
card(s) by the DHCP server.
–
Alarm for an optional service card.
•
Flashing (240/minute): Initialise failed
•
Flashing (60/minute): WAN connection session
malfunction (router malfunction)
For more information, refer to "8.6.2 WAN
Connection".
BATT ALARM
Red
Alarm indication
•
OFF: Normal
•
ON: Alarm
MASTER
Green
Master unit status indication
•
ON: Master
Slave unit status indication
•
Flashing: Running as Backup Master unit
Amber
Master unit status indication
•
Flashing: Factory default
Slave unit status indication
•
ON: Slave
•
Flashing: Factory default/Starting up
Red
Master unit status indication
•
ON: Recovered (Waiting to be switched with
Backup Master unit)
Slave unit status indication
•
Flashing: Isolated from Master unit
148
Installation Manual
4.3.1 Mother Board
Содержание KX-NS1000
Страница 40: ...40 Installation Manual 1 4 Data Security ...
Страница 76: ...76 Installation Manual 2 3 3 System Capacity ...
Страница 108: ...108 Installation Manual 3 1 3 Using CTI Applications ...
Страница 191: ...Example KX NT346 Ethernet Straight Cable To a PC Installation Manual 191 4 11 2 LAN Connections for IP Telephones ...
Страница 267: ...the priority Installation Manual 267 5 8 3 Setting LLDP Parameters ...
Страница 312: ...312 Installation Manual 5 12 Automatic Configuration of Mailboxes ...
Страница 318: ...318 Installation Manual 6 2 Methods of Stacking PBXs ...
Страница 332: ...332 Installation Manual 7 1 6 Troubleshooting by Error Log ...
Страница 400: ...400 Installation Manual 8 6 26 WAN Port Mirroring ...
Страница 414: ...414 Installation Manual 9 3 7 PCMPR Software File Version 004 1xxxx ...