![Panasonic KX-HTS32 Скачать руководство пользователя страница 104](http://html.mh-extra.com/html/panasonic/kx-hts32/kx-hts32_getting-started_262466104.webp)
5.3 System Initialization Procedure
The system data can be returned to its initial state by following the procedure below.
1.
While pressing and holding the Initialize Switch, turn the power ON. The LED will light amber.
2.
Continue holding down the Initialize Switch (to confirm the holding). The LED will flash amber at a rate of
240 flashes/minute.
3.
Initialization begins. The LED will flash green at a rate of 240 flashes/minute.
4.
At this time the Initialize Switch may be released.
5.
Operation begins in the initialized state. The LED will light green.
All data will be erased. Data that is erased includes Voice Message data, call logs, etc. The settings for
the PBX as well as all optional service cards will be initialized to their default values.
Note
•
After the PBX is initialized, you can restore system data to the PBX that has been backed up
earlier. For details about backing up and restoring system data, refer to "5.1 System Data Backup
and Restore".
•
After the PBX is initialized, you must set up the mandatory settings required for PBXs. For details
refer to "3.9.4.1 Easy Setup Wizard".
5.4 System Logging
This is a function that saves the system information to the HTS’ internal storage and outputs it to
administrators.
System Log
The following types of Syslog information can be checked from the Web-MC. (The latest 100 logs are
displayed.)
- syslog_major
Stores logs of major system errors
- syslog_minor
Stores logs of minor system errors
- syslog_update
Stores logs of version up operations
Syslog files and other than those described above can be exported to your PC by operating the Web-MC.
For more information, refer to 4.4.2 Maintenance—[3-2] Utility—System Log in Programming Item List.
Error Log
When system failure occurs, relevant information is logged into the Error Log.
Upon the occurrence of a major error log, the Status LED lights up red to notify the user that an anomaly
has occurred. The status LED will light green when the Error Log (Major/Minor) is cleared.
Error Log information (Major/Minor) can be checked on the Web-MC.
Error Log information can be exported to your PC. For more information, refer to 4.4.2 Maintenance—[3-2]
Utility—System Log in Programming Item List.
The Error Log displays up to the latest 100 Major and 100 Minor error records.
You may issue a failure notice via email when saving records in the Error Log.
KX-HTS series can send a mail for each time a major/minor error occurs. You can set for determining
whether or not to send such email notice using the Web-MC. For more information, refer to 4.4.3
Maintenance—[3-3] Utility—Email Notification in Programming Item List.