(Cause and Countermeasure)
As shown in the chart above, the total handshaking time must be reduced, but because of the
long distance connection and linking of several stations, the line connection time cannot be
reduced. Accordingly, the following countermeasures should betried.
(A)... As the 35 sec. count is started directly after dialing or directly after the START button has
been pressed for models with a START button, the other party should be called manually, if
possible. Another possibility is entering two pausesat the end of the auto dial number on the
transmission side. Then the count start time can be delayed for 2 pauses (about 10 sec.).
Cause 2:
Erroneous detection because of an echo or an echo canceler.
(Echo/Echo Canceler)
The signal from FAX1 reaches FAX2 via stations 1 and 2, but the reflection signal at station 2 also
returns via station 1 (echo). As the distance between station 1 and station 2 is far, the echo
returns to FAX 1 at a max of 600 msec after transmission.There is a possibility that this signal is
detected erroneously as the signal from FAX2. For a normal call, there is also a possibility that
the echo of their own voice will make the call difficult to understand. For this reason, each station
(station1 and station 2) attaches echo cancelers (S1 and S2) for international lines or long
distance lines. For the echo canceler, the level of the transmission signal from FAX 1 is compared
with the level of the reception signal from FAX2. When the transmissionsignal is larger, S1 is
closed while S2 is opened when it is smaller. In other words, for transmission from FAX1, S1 is
closed and S2 is open, so that the echo does not return to FAX1.
(Causes and Countermeasures)
106
Содержание KX-FP342CX
Страница 34: ...3 Open the back cover 4 Remove the jammed recording paper 34 ...
Страница 38: ...1 Open the front cover by pulling up the center part Removethe jammed document carefully 38 ...
Страница 45: ...5 1 DISASSEMBLY FLOW CHART 5 1 1 UPPER CABINET SECTION 45 ...
Страница 48: ...5 2 2 HOW TO REMOVE THE OPERATION PANEL BLOCK 48 ...
Страница 49: ...5 2 3 HOW TO REMOVE THE OPERATION BOARD AND LCD 49 ...
Страница 50: ...5 2 4 HOW TO REMOVE THE IMAGE SENSOR CIS 50 ...
Страница 51: ...5 2 5 HOW TO REMOVE THE THERMAL HEAD 51 ...
Страница 52: ...5 2 6 HOW TO REMOVE THE PLATEN ROLLER AND BACK COVER 52 ...
Страница 53: ...5 2 7 HOW TO REMOVE THE PICKUP ROLLER 53 ...
Страница 54: ...5 2 8 HOW TO REMOVE THE CASSETTE LEVER 54 ...
Страница 55: ...5 2 9 HOW TO REMOVE THE BOTTOM FRAME 55 ...
Страница 56: ...5 2 10 HOW TO REMOVE THE DIGITAL ANALOG POWER SUPPLY SENSOR BOARDS AND AC INLET 56 ...
Страница 57: ...5 2 11 HOW TO REMOVE THE MOTOR BLOCK AND SEPARATION ROLLER 57 ...
Страница 58: ...5 2 12 HOW TO REMOVE THE GEARS OF MOTOR BLOCK 58 ...
Страница 59: ...5 3 INSTALLATION POSITION OF THE LEAD WIRES 59 ...
Страница 72: ...2 Left margin Top margin 3 Thermal head 1 dot 72 ...
Страница 75: ...CROSS REFERENCE PROGRAM MODE TABLE 6 4 2 PROGRAM MODE TABLE 75 ...
Страница 79: ...Note The above values are the default values 6 5 3 HISTORY 79 ...
Страница 88: ...Fig B 88 ...
Страница 96: ...6 6 4 12 A BLANK PAGE IS RECEIVED 96 ...
Страница 113: ...SERVICE FUNCTION TABLE Note If the problem remains see the following Countermeasure flow chart 113 ...
Страница 114: ...CROSS REFERENCE TEST FUNCTIONS 114 ...
Страница 115: ...CROSS REFERENCE TEST FUNCTIONS 115 ...
Страница 116: ...CROSS REFERENCE TEST FUNCTIONS 116 ...
Страница 117: ...CROSS REFERENCE TEST FUNCTIONS 117 ...
Страница 118: ...118 ...
Страница 119: ...119 ...
Страница 120: ...120 ...
Страница 125: ...125 ...
Страница 130: ...6 6 7 1 CHECK THE STATUS OF THE DIGITAL BOARD 130 ...
Страница 132: ...CROSS REFERENCE NG EXAMPLE CHECK THE STATUS OF THE DIGITAL BOARD POWER SUPPLY BOARD SECTION 132 ...
Страница 136: ...3 No ring tone or No bell CROSS REFERENCE CHECK SHEET 136 ...
Страница 139: ...6 6 9 2 TROUBLESHOOTING FLOW CHART 139 ...
Страница 140: ...140 ...
Страница 141: ...141 ...
Страница 145: ...CROSS REFERENCE TEST FUNCTIONS 6 6 13 THERMAL HEAD SECTION Refer to THERMAL HEAD 145 ...
Страница 146: ...7 CIRCUIT OPERATIONS 7 1 CONNECTION DIAGRAM 146 ...
Страница 149: ...7 3 CONTROL SECTION 7 3 1 BLOCK DIAGRAM 7 3 2 MEMORY MAP 149 ...
Страница 150: ...7 3 3 ASIC IC501 This custom IC is used for the general FAX operations 150 ...
Страница 152: ...152 ...
Страница 198: ...8 3 2 ITU T No 2 TEST CHART 198 ...
Страница 199: ...9 FIXTURES AND TOOLS 199 ...
Страница 200: ...10 CABINET MECHANICAL AND ELECTRICAL PARTS LOCATION 10 1 GENERAL SECTION 200 ...
Страница 201: ...10 2 OPERATION PANEL SECTION 201 ...
Страница 202: ...10 3 BACK COVER SECTION 202 ...
Страница 203: ...203 ...
Страница 204: ...10 4 UPPER CABINET SECTION 204 ...
Страница 205: ...10 5 LOWER CABINET P C BOARD SECTION 205 ...
Страница 206: ...CROSS REFERENCE MOTOR SECTION 10 6 MOTOR SECTION 206 ...
Страница 207: ...10 7 ACTUAL SIZE OF SCREWS 11 ACCESSORIES AND PACKING MATERIALS 207 ...
Страница 232: ...SW502 SW501 CN501 CHECK PFUP1301ZA 1 3 KX FP342CX SENSOR BOARD PCB5 ...
Страница 241: ...CN501 1 COVER OPEN 2 READ 3 GND SW501 READ SW502 COVER OPEN SW 1 3 2 4 KX FP342CX SENSOR BOARD PCB5 ...