14-8
FP0
Item
Add-
ress
Name
Default
value
Descriptions
31
Wait time setting for
multi-frame
communication
6500 ms
(K2600)
10 ms to 81900 ms (K4 to K32760)
Used of default setting (K2600/6500
ms) is recommended.
Time
setting
34
Constant value settings
for scan time
0 ms
(K0)
2.5 ms to 160 ms (K1 to K64 ): Scans
once each specified time interval.
0 (K0):Normal scan
Do not set
X0 as
high-
speed
counter.
CH0
Do not set X0 as high-speed
counter.
2-phase input (X0, X1)
2-phase input (X0, X1),
Reset input (X2)
Incremental input (X0)
Incremental input (X0), Reset input
(X2)
Decremental input (X0)
Decremental input (X0),
Reset input (X2)
Individual input (X0, X1)
Individual input (X0, X1),
Reset input (X2)
Direction decision (X0, X1)
Direction decision (X0, X1),
Reset input (X2)
Input
setting
400
High-speed
counter
mode
settings
(X0 to X2)
Setting by
progra-
mming tool
software
Do not set
X1 as
high-
speed
counter.
CH1
Do not set X1 as high-speed
counter.
Incremental input (X1)
Incremental input (X1), Reset input
(X2)
Decremental input (X1)
Decremental input (X1), Reset input
(X2)
Note1) If the operation mode is set to 2-phase, individual, or direction differentiation, the setting for CH1
is invalid.
Note2) If reset input settings overlap, the setting of CH1 takes precedence.
Note3) If system register 400 to 403 have been set simultaneously for the same input relay, the following
precedence order is effective: [High-speed counter] ‘[Pulse catch]’ [Interrupt input].
Содержание FP0 Series
Страница 14: ...Table of Contents FP0 xii ...
Страница 16: ...Overview FP0 1 2 ...
Страница 82: ...S LINK Control Unit FP0 4 2 ...
Страница 95: ...Chapter 5 I O Allocation 5 1 I O Number 5 3 5 2 Control Unit 5 4 5 3 Expansion I O Unit 5 5 ...
Страница 96: ...I O Allocation FP0 5 2 ...
Страница 100: ...I O Allocation FP0 5 6 5 3 Expansion I O Unit ...
Страница 102: ...Installation FP0 6 2 ...
Страница 112: ...Installation FP0 6 12 6 5 Installation Using FP0 Flat Type Mounting Plate ...
Страница 114: ...Wiring FP0 7 2 ...
Страница 198: ...High speed Counter Pulse Output PWM Output FP0 9 34 9 5 PWM Output Function ...
Страница 200: ...General use Serial Communications FP0 10 2 ...
Страница 210: ...Self Diagnostic and Troubleshooting FP0 11 2 ...
Страница 220: ...Specifications FP0 12 2 ...
Страница 234: ...Dimensions FP0 13 2 ...
Страница 241: ...Dimensions FP0 13 9 13 6 Detailed Specifications of Cables 13 6 Detailed Specifications of Cables ...
Страница 243: ...Chapter 14 Appendix ...
Страница 380: ...14 138 14 7 ASCII Codes ...