14-102
Num-
ber
Name Boolean
Operand
Description
Steps
F262
P262
Retrieving
data from
character
strings (left
side)
LEFT
S1, S2, D
These instructions retrieve a specified number of
characters from the left side of the character string.
8
F263
P263
Retrieving a
character
string from a
character
string
MIDR
S1, S2, S3,
D
These instructions retrieve a character string
consisting of a specified number of characters from
the specified position in the character string.
10
F264
P264
Writing a
character
string to a
character
string
MIDW
S1, S2, D,
n
These instructions write a specified number of
characters from a character string to a specified
position in the character string.
12
F265
P265
Replacing
character
strings
SREP
S, D, p, n
A specified number of characters in a character
string are rewritten, starting from a specified
position in the character string.
12
Integer type data processing instructions
F270
P270
Maximum
value (word
data (16-bit))
MAX
PMAX
S1, S2, D
Searches the maximum value in the word data
table between the “S1” and “S2”, and stores it in
the “D”. The address relative to “S1” is stored in
“D+1”.
8
F271
P271
Maximum
value (double
word data
(32-bit))
DMAX
PDMAX
S1, S2, D
Searches for the maximum value in the double
word data table between the area selected with
“S1” and “S2”, and stores it in the “D”. The address
relative to “S1” is stored in “D+2”.
8
F272
P272
Minimum
value (word
data (16-bit))
MIN
PMIN
S1, S2, D
Searches for the minimum value in the word data
table between the area selected with “S1” and “S2”,
and stores it in the “D”. The address relative to “S1”
is stored in “D+1”.
8
F273
P273
Minimum
value (double
word data
(32-bit))
DMIN
PDMIN
S1, S2, D
Searches for the minimum value in the double word
data table between the area selected with “S1” and
“S2”, and stores it in the “D”. The address relative
to “S1” is stored in “D+2”.
8
F275
P275
Total and
mean values
(word data
(16-bit))
MEAN
PMEAN
S1, S2, D
The total value and the mean value of the word
data with sign from the area selected with “S1” to
“S2” are obtained and stored in the “D”.
8
F276
P276
Total and
mean values
(double word
data (32-bit))
DMEAN
PDMEAN
S1, S2, D
The total value and the mean value of the double
word data with sign from the area selected with
“S1” to “S2” are obtained and stored in the “D”.
8
Содержание FP0 Series
Страница 14: ...Table of Contents FP0 xii ...
Страница 16: ...Overview FP0 1 2 ...
Страница 82: ...S LINK Control Unit FP0 4 2 ...
Страница 95: ...Chapter 5 I O Allocation 5 1 I O Number 5 3 5 2 Control Unit 5 4 5 3 Expansion I O Unit 5 5 ...
Страница 96: ...I O Allocation FP0 5 2 ...
Страница 100: ...I O Allocation FP0 5 6 5 3 Expansion I O Unit ...
Страница 102: ...Installation FP0 6 2 ...
Страница 112: ...Installation FP0 6 12 6 5 Installation Using FP0 Flat Type Mounting Plate ...
Страница 114: ...Wiring FP0 7 2 ...
Страница 198: ...High speed Counter Pulse Output PWM Output FP0 9 34 9 5 PWM Output Function ...
Страница 200: ...General use Serial Communications FP0 10 2 ...
Страница 210: ...Self Diagnostic and Troubleshooting FP0 11 2 ...
Страница 220: ...Specifications FP0 12 2 ...
Страница 234: ...Dimensions FP0 13 2 ...
Страница 241: ...Dimensions FP0 13 9 13 6 Detailed Specifications of Cables 13 6 Detailed Specifications of Cables ...
Страница 243: ...Chapter 14 Appendix ...
Страница 380: ...14 138 14 7 ASCII Codes ...