14-96
Num-
ber
Name Boolean
Operand
Description
Steps
High speed counter/Pulse output instruction for FP
Σ
/FP-X
F0
High-speed
counter and
Pulse output
controls
MV
S, DT90052
Performs high-speed counter and Pulse output
controls according to the control code specified by
“S”. The control code is stored in DT90052.
5
FP
Σ
:
S, DT90044
FP-X:
S, DT90300
Transfers (S+1, S) to high-speed counter and
Pulse output elapsed value area (DT90045,
DT90044).
7
F1
Change and
read of the
elapsed value
of high-speed
counter and
Pulse output
DMV
FP
Σ
:
DT90044, D
FP-X:
DT90300, D
Transfers value in high-speed counter and Pulse
output elapsed value area (DT90045, DT90044) to
(D+1, D).
7
F166
Target value
much on
(with channel
specification)
HC1S
n, S, D
Turns output Yn on when the elapsed value of the
built-in high-speed counter reaches the target value
of (S+1, S).
11
F167
Target value
much off
(with channel
specification)
HC1R
n, S, D
Turns output Yn off when the elapsed value of the
built-in high-speed counter reaches the target value
of (S+1, S).
11
F171
Pulse output
(with channel
specification)
(Trapezoidal
control and
home return)
SPDH
S, n
Positioning pulses are output from the specified
channel, in accordance with the contents of the
data table that starts with S.
5
F172
Pulse output
(with channel
specification)
(JOG
operation)
PLSH
S, n
Pulse strings are output from the specified output,
in accordance with the contents of the data table
that starts with S.
5
F173
PWM output
(with channel
specification)
PWMH
S, n
PWM output is output from the specified output, in
accordance with the contents of the data table that
starts with S.
5
F174
Pulse output
(with channel
specification)
(Selectable
data table
control
operation )
SP0H
S, n
Outputs the pulses from the specified channel
according to the data table specified by S.
5
F175
Pulse output
(Linear
interpolation)
SPSH
S, n
Pulses are output from channel, in accordance with
the designated data table, so that the path to the
target position forms a straight line.
5
F176
Pulse output
(Circular
interpolation)
SPCH
S, n
Pulses are output from channel, in accordance with
the designated data table, so that the path to the
target position forms an arc.
5
Содержание FP0 Series
Страница 14: ...Table of Contents FP0 xii ...
Страница 16: ...Overview FP0 1 2 ...
Страница 82: ...S LINK Control Unit FP0 4 2 ...
Страница 95: ...Chapter 5 I O Allocation 5 1 I O Number 5 3 5 2 Control Unit 5 4 5 3 Expansion I O Unit 5 5 ...
Страница 96: ...I O Allocation FP0 5 2 ...
Страница 100: ...I O Allocation FP0 5 6 5 3 Expansion I O Unit ...
Страница 102: ...Installation FP0 6 2 ...
Страница 112: ...Installation FP0 6 12 6 5 Installation Using FP0 Flat Type Mounting Plate ...
Страница 114: ...Wiring FP0 7 2 ...
Страница 198: ...High speed Counter Pulse Output PWM Output FP0 9 34 9 5 PWM Output Function ...
Страница 200: ...General use Serial Communications FP0 10 2 ...
Страница 210: ...Self Diagnostic and Troubleshooting FP0 11 2 ...
Страница 220: ...Specifications FP0 12 2 ...
Страница 234: ...Dimensions FP0 13 2 ...
Страница 241: ...Dimensions FP0 13 9 13 6 Detailed Specifications of Cables 13 6 Detailed Specifications of Cables ...
Страница 243: ...Chapter 14 Appendix ...
Страница 380: ...14 138 14 7 ASCII Codes ...