11. Scroll down to, and select BAT TEMP.
Figure 6.26: Battery temperature calibration 6
12. Enter the value recorded in step 8.
Figure 6.27: Battery temperature calibration 7
Battery temperature offset is now calibrated all that remains is to check the circuitry is working by testing the minimum temperature
extreme to verify the offset readings are within acceptable limits.
13. Select the 27 k
Ω
resistor value on the dummy battery and repeat steps 5 to 8. If the reading is outside the range 238- 307 then
there is a fault and further investigation is required.
Battery Voltage High Calibration
1.
Connect the dummy battery to the phone as shown for Battery Temperature calibration.
Содержание EB-GD35
Страница 59: ...http cxema ru EB GD35 EB GD35C 59 8 CIRCUIT DIAGRAMS Figure 8 1 GD35 Top Level Schematic Figure 8 2 Figure 8 3 ...
Страница 60: ...http cxema ru EB GD35 EB GD35C 61 Figure 8 2 Baseband Top Level Figure 8 4 Figure 8 5 ...
Страница 61: ...http cxema ru EB GD35 EB GD35C 62 Figure 8 3 RF Top Level Figure 8 6 Figure 8 7 ...
Страница 62: ...http cxema ru EB GD35 EB GD35C 63 Figure 8 4 Baseband Peripherals ...
Страница 63: ...http cxema ru EB GD35 EB GD35C 64 Figure 8 5 Baseband Processor GD35C only ...
Страница 64: ...http cxema ru EB GD35 EB GD35C 65 Figure 8 6 RF Front End ...
Страница 65: ...http cxema ru EB GD35 EB GD35C 66 Figure 8 7 RF IF and Synthesiser ...