http://cxema.ru
EB-GD35 EB-GD35C
42
6.
If the measured power is not -90 ±1, then make the following calculation:
Record the result.
7.
At the channel box, press F7 to view data.
8.
Select TRIM OTHER and make a note of the RSSI COMP GSM reading.
Figure 6.15: RSSI reading 1
9.
At the Channel box, press F6 to program data.
Figure 6.16: RSSI reading 2
RSSI offset value
= [-(90 + MEASURED RSSI VALUE)] x 2
= [ -90 - MEASURED RSSI VALUE] x 2,
for example
[-(90 + (95))] x 2
= [-90 - (-95)] x 2
= 10