http://cxema.ru
EB-GD35 EB-GD35C
38
Calibration of output power on each power level
1.
Power on the telephone in Test Set Mode.
2.
Scroll down the menu until CHANGE CH <62> is highlighted and then press ENTER.
3.
Scroll down the menu until PL <5> is highlighted. Use the left and right cursor keys to select <14>. Press ENTER.
4.
Scroll down the menu until TX DATA <OFF> is highlighted. Using the left / right cursor keys, highlight <NRL 1> and press
ENTER.
5.
The channel box screen should appear as shown below.
Figure 6.8: Software Screen 2
6.
If measured power is in the range of the target power, then proceed to step 10.
7.
At the Channel box, press F7 to view the TRIM for the mid-channel.
Figure 6.9: Power level view 1
NOTE:
To ensure that the telephone operates within set SAR margins, Panasonic recommends that a power meter capable
of measurement to an accuracy of ±0.2 dB is used when calibrating power levels. Use of a less accurate power meter
may result in the telephone failing to meet SAR standards.
Содержание EB-GD35
Страница 59: ...http cxema ru EB GD35 EB GD35C 59 8 CIRCUIT DIAGRAMS Figure 8 1 GD35 Top Level Schematic Figure 8 2 Figure 8 3 ...
Страница 60: ...http cxema ru EB GD35 EB GD35C 61 Figure 8 2 Baseband Top Level Figure 8 4 Figure 8 5 ...
Страница 61: ...http cxema ru EB GD35 EB GD35C 62 Figure 8 3 RF Top Level Figure 8 6 Figure 8 7 ...
Страница 62: ...http cxema ru EB GD35 EB GD35C 63 Figure 8 4 Baseband Peripherals ...
Страница 63: ...http cxema ru EB GD35 EB GD35C 64 Figure 8 5 Baseband Processor GD35C only ...
Страница 64: ...http cxema ru EB GD35 EB GD35C 65 Figure 8 6 RF Front End ...
Страница 65: ...http cxema ru EB GD35 EB GD35C 66 Figure 8 7 RF IF and Synthesiser ...