31
8.4.2.
BF ADJUSTMENT(2) [ Infinity adjustment ]
[ PREPARATION ]
1. Perform the “8.3 Execute the Adjustment software“DscCalDi.exe”” in advance.
[ CAUTION ]
1. Do not apply any vibration to the camera during adjustment.
[ ADJUSTMENT SETTINGS ]
1. Click on the pull down menu tag of the “Test”.
(The Test item list is displayed.)
2. Choose the “Monitor” so that the LCD display displays monitoring image.
3. Set the camera unit and collimeter as follows.
Make a gap between DSC unit and Collimeter, to prevent touching each other.
4. Adjust the collimeter position so that the center of the chart is displayed to center of the LCD display.
By changing the Zoom condition, confirm that the center of the chart is displayed to center of the LCD display.
[ ADJUSTMENT ]
1. Click on the pull down menu tag of the “Test”.
(The Test item list is displayed.)
2. Choose the “Infinity Cal.” in order to execute adjustment.
NOTE:
It takes few minutes for adjustment process.