3. When the adjustment is completed, the “Focus Result value list” is displayed.
4. Compare the Value displayed on the PC monitor and the following table.
If the adjustment value is out of specification, replace the Lens unit and try it again.
5. After confirmation (Data comparison) has been completed, click on “OK”.
[ AFTER ADJUSTMENT ]
NOTE:
If you want to perform other adjustments continiously, click on the pull down menu tag of the “Test” and choose the “OFF” in
stead of perform the following 1 to 3.
(The LCD display becomes black fade.)
Do not perform the same adjustment, continuously.
If it is necessary to perform the same adjustment, follow the following 1 to 3.
1. Close the “DscCalDi.exe” by clicking on the “X” located on the top right corner.
The LCD of the Camera unit becomes black fade.
2. Turn “off” the power switch of the camera unit.
3. Disconnect the USB cable.
Содержание DMC-F3P
Страница 16: ...16 4 Specifications ...
Страница 23: ...23 7 3 2 Removal of the LCD Unit Fig D3 Fig D4 7 3 3 Removal of the Flash P C B Lens Unit Fig D5 Fig D6 ...
Страница 24: ...24 Fig D7 7 3 4 Removal of the Front Top Case Unit Fig D8 Fig D9a ...
Страница 25: ...25 Fig D9b Fig D10 7 3 5 Removal of the Main P C B and Top Operation P C B Battery Case Unit Fig D11 ...