Notes:
Two different Flash Patterns can be defined in Flash Timers 1 and 2, FF1 1 01 (0001-0002).
Related Programming:
Flash Timer 1 for Trunk Line (pg. 1-115) FF1 1 01 0001 Hold (1-255) Hold
Flash Timer 2 for Trunk Line (pg. 1-116) FF1 1 01 0002 Hold (1-255) Hold
Flash Pattern
(all CPCs) - Version 1.0 or higher
Set the pattern number that will be used for flash signals to the CO on the T1
channel.
FF2 2 BSSCC 03 01 Hold (0 or 1) Hold
0=Flash Pattern #1 (default)
BSSCC: T1 (E&M Tie) Channel Position
B=Cabinet no. 1-6
SS=Slot no. 01-12
CC=Channel no. 01-24
1=Flash Pattern #2
$
",9 59
Not Used
(all CPCs) - Version 1.0 or higher
FF2 2 BSSCC 03 02 Hold
$