FF1: System Programming
Section 400-Programming
Page 1-178
●
DBS 576 (USA) issued 05/20/98
576-13-400
FF1
System
FF2
Trunks
FF3
Extensions
FF4
FF-/Soft Keys
FF5
Groups
FF6
TRS/ARS
0
System
Configuration
FF7
Applications
FF8
Maintenance
Introduction
Appendix A
Appendix B
FF1
System
FF2
Trunks
FF3
Extensions
FF4
FF-/Soft Keys
FF5
Groups
FF6
TRS/ARS
0
System
Configuration
FF7
Applications
FF8
Maintenance
Introduction
Appendix A
Appendix B
Notes:
Adjust the default setting(s) in this address whenever extension users have difficulty hearing calls on a
particular trunk, or the volume is too loud on it.
The default settings in this address are intended for different trunk types as follows:
Trunk Pad Class 1: for Analog CO
Trunk Pad Class 2: for Analog CO/loss compensation
Trunk Pad Class 3: for Private Line CES (Centralized Extension System) #1
Trunk Pad Class 4: for Private Line CES #2
Trunk Pad Class 5: for LDT (Loop Dialing Trunk) Standard
Trunk Pad Class 6: for Private Line CES #4 (no CES #3)
Trunk Pad Class 7: for ISDN T-point
Trunk Pad Class 8: for AC/15 #1 (U.K. only)
Trunk Pad Class 9: for AC/15 #2 (U.K. only)
Trunk Pad Class 10: Not Used
Trunk Pad Class 11: for AC/15 System Connection (U.K. only)
Trunk Pad Class 12: Not Used
Trunk Pad Class 13: for 0 dB Highway
Trunk Pad Class 14: for 4 dB Highway
Trunk Pad Class 15: for 8 dB Highway
Trunk Pad Class 16: for Data Highway/ISDN
Related Programming:
Trunk Digital Pad Class Assignment (pg. 2-36) for analog CO trunks FF2 0 BSSC 08 Hold (1-16) Hold
Trunk Digital Pad Class Assignment (pg. 2-58) for analog E&M tie trunks FF2 0 BSSC 08 Hold (1-16) Hold
Digital Pad Settings for Trunk Pad Class
(all CPCs) - Version 1.0 or higher
Set volume adjustments for phone connections between Trunk Pad
Classes 1-16 (the transmitting end of the connection) and 30 other pad
classes (the receiving end of the connection).
FF1 8 02 (0001-0480) Hold (0-31) Hold
Volume Adjustment Setting:
0= 0 dB
1=
−
2 dB
2=
−
4 dB
3=
−
6 dB
4=
−
8 dB
5=
−
10 dB
6=
−
12 dB
7=
−
14 dB
8=
−
16 dB
9=
−
18 dB
10=
−
20 dB
11=
−
22 dB
12=
−
24 dB
13=
−
26 dB
14=
−
28 dB
15=
−
30 dB
16 = 0 dB
17 = +2 dB
18 = +4 dB
19 = +6 dB
20 = +8 dB
21 = +10 dB
22 = +12 dB
23 = +14 dB
24 = +16 dB
25 = +18 dB
26 = +20 dB
27 = +22 dB
28 = +24 dB
29 = +26 dB
30 = +28 dB
31 = +30 dB
0001-0030=transmitted by Trunk Pad Class 1
0031-0060=transmitted by Trunk Pad Class 2
0061-0090=transmitted by Trunk Pad Class 3
0091-0120=transmitted by Trunk Pad Class 4
0121-0150=transmitted by Trunk Pad Class 5
0151-0180=transmitted by Trunk Pad Class 6
0181-0210=transmitted by Trunk Pad Class 7
0211-0240=transmitted by Trunk Pad Class 8
0241-0270=transmitted by Trunk Pad Class 9
0271-0300=transmitted by Trunk Pad Class 10
0301-0330=transmitted by Trunk Pad Class 11
0331-0360=transmitted by Trunk Pad Class 12
0361-0390=transmitted by Trunk Pad Class 13
0391-0420=transmitted by Trunk Pad Class 14
0421-0450=transmitted by Trunk Pad Class 15
0451-0480=transmitted by Trunk Pad Class 16
(see tables, next page)