13
Step
Category step
Setting
Screen menu names
Operation
Air
conditioning
operations
only
Distribution rate
display only
Quantity used,
charges display
Time
Load
Time
Load
6
Distribution
related
Distribution modes (time/load)
Distribution mode settings
Power distribution calculation
target*
3
Distribution mode settings
Energy saving distribution setting
Distribution mode settings
*
4
*
4
Distribution of gas for power
generation
Distribution mode settings
*
5
*
5
Setting the monthly cut-off days
Calendr sttngs for distr calc
*
6
Setting the regular hour range
Calendr sttngs for distr calc
Setting specified days
Calendr sttngs for distr calc
Currency for electricity or gas
charges*
7
Distribution Ratio settings
Setting the capacity of the indoor
units*
8
I/D unit settings
Setting the capacity of the electric
heater*
9
I/D unit settings
7
Scheduling
related
Schedule for a single day
Schedule setting
Allocating a schedule to a calendar Calendar
Schedule group
I/D unit settings
8
Event control
Input point (names and
conditions)*
10
Event control
Output point (names and
operation)*
11
Event control
9
Network related*
12
IP address, net mask, DHCP, etc.
Network settings
Setting to send alarm mails
Email settings
User ID, password, privileges
Web user settings
10
Intelligent
controller related
Buzzer volume
Display/Volume settings
Brightness of the back light
Display/Volume settings
Auto logout time
Display/Volume settings
Identification number
Initialize
Initialise the days accumulated
data*
13
Initialize
*1 Attention needs to be paid to administration divisions when devices such as systems controllers are to be used in conjunction with this unit.
*2 Settings required when area administration is to be performed.
*3 Select the object of calculations for electricity distributing from the following:
Operating hours
Select when consideration is to be paid to the electricity for the indoor units. The electricity for outdoor units and indoor units are both
loaded into this unit and distributed.
Thermostat on times Select when no consideration is to be paid to the electricity for the indoor units. The electricity for outdoor units only is loaded into this
unit and distributed.
*4 If the air conditioning units included in the system are multi-function types supporting simultaneous heating and cooling or ice thermal storage models, settings
are required.
*5 Settings are required only when units are GHP with generators.
*6 Settings are required when only the accumulation operating time is to be managed.
*7 This must be set if you want to display charges.
*8 This only needs to be set for interface adaptors.
*9 This is used when calculating load distributing.
*10 Set items such as batch startup and stopping from external input.
*11 Set items such as batch alarm output to external devices.
*12 Required when logging in through a network device to operate and monitor.
*13 Clears the data calculated from test operation of the air conditioning units before hand over.
Setting