Removal Procedure For Cross Flow Fan
Remote control reset
If the display is chaotic or can not be adjusted,
Remove the back lid of the remote control
and you will find the resetting terminals and
shorten the two terminals using a screw driver
to reset.
Resetting terminals
Fig 14
52
1. Release the two fixing screws on the left side of the evaporator
and lift up the evaporator slightly. (Fig. 10)
2.Loose the fixing screw of the cross flow fan. (Fig. 11)
Fig. 10
Fig. 11
Fixing Screw
3.After removing the bearing (refer to fig12) , indoor fan can be
taken out from the left side.
Bearing
4. Lift up the indoor fan slightly, and then pull the fan motor out.
Fig 13
Fan motor
Fig 12
CS-YW9DKE / CU-YW9DKE / CS-YW12DKE / CU-YW12DKE