17
Automatic Fan Speed
During Soft Dry Operation, use remote controller to select Auto Fan Speed mode.
Indoor Fan Speed is at “Lo-”
70
T2
40
T1
Slo
Lo-
OFF
ON
OFF
10
6
70
T2
40
T1
10
Slo
Slo
Lo-
ON
OFF
OFF
OFF
Indoor
fan
Compressor
Time Graph for soft dry operation
a b c
d e
f
g
h i
j
k
l
m n
o
p q
r
s
t
u
Evaporator
temperature
10 C
o
2 C
o
Basic Time
Comp.
Indoor Fan
Outdoor Fan
Operation Indicator
6
6
6
1
6
1
1
4
Operation status
Time
Operate
Stop
Super
Low
Super
Low
Super
Low
Super
Low
Low
1.5
Cooling mode operation activated
Intake Air temp
1.0
Cooling mode operation stopped
Soft mode operation activated
Soft dry mode operation stop
Cooling Mode Operation
Soft Dry Mode Operation
Soft Dry Mode Operation Stopped
Compressor Test Operation Control
Anti Freezing Control
a - c , p - r
c - p , r - u
e - f
j - l
q - t
:
:
:
:
:
Slo
Slo
Slo
Slo
Slo
Slo
Slo
Slo
Slo
Slo
Slo
4-way Valve
CS-YW9DKE / CU-YW9DKE / CS-YW12DKE / CU-YW12DKE