9.2.5. CONNECT THE CABLE TO THE
INDOOR UNIT
1. The inside and outside connecting cable can be connected
without removing the front grille.
2. Connecting cable between indoor unit and outdoor unit
shall
be
approved
polychloroprene
sheathed
5
(YW9DKE,YW12DKE) x 1.5 mm
2
flexible cord, type
designation 245 IEC 57 or heavier cord.
ıı ı
ı
ˇı
ˇ ı
ˇ ı
ˇ ıEnsure the color of wires of outdoor unit and the
terminal Nos. are the same to the indoor’s respectively.
ıı ı
ı
ˇı
ˇ ı
ˇ ı
ˇ ıEarth lead wire shall be longer than the other lead wires
as shown in the figure for the electrical safety in case of
the slipping out of the cord from the anchorage.
ıı ı
ı
ˇı
ˇ ı
ˇ ı
ˇ ıSecure the cable onto the control board with the holder
(clamper).
34
CS-YW9DKE / CU-YW9DKE / CS-YW12DKE / CU-YW12DKE
connector
1 2 3 4
(L)
(N)
CS-YW9DKE
CS-YW12DKE