34
<Operating procedure>
1.
Connect the additional remote cameras to be introduced
and the unit to the network within the same subnet.
2.
Select the [AUTO IP SET] SYSTEM menu, turn the F1
dial to display [KEEP], then press the F1 dial.
AUTO IP SET 1/1
AUTO SET
KEEP
NO?
TOTAL
EXEC
NEW
AW-UE70
The number of devices currently being managed by the unit (All
remote cameras and the newly detected number of devices are
displayed in [NEW] and [TOTAL].)
NEW
:
Newly detected cameras
TOTAL :
The number of all devices currently being managed by
the unit + Number of newly detected devices
3.
Set [EXEC] (F4 dial) to [SETTING], then press the F4
dial.
“Auto IP setting” starts.
The “AUTO IP SETTING” message is displayed while “auto IP
setting” is being performed.
z
The “COMPLETE” message is displayed when the entire process
is successful.
The remote cameras can now be operated from the unit.
z
The “IP Duplicate!” message is displayed when the IP address of
an already running device and the IP address of a remote camera
being added are the same, and the link setting is not made.
Check the IP addresses of the additional remote cameras to be
introduced, and then perform the “auto IP setting” operation again.
z
The “SET UP ERR” message is displayed when IP address setting
fails.
The cause of the problem is likely to be a network malfunction.
Check the connection status of the hub and LAN cables, and then
retry the “auto IP setting” operation.
Connection device detection
z
z
When the number of new devices detected by [RENEW] or [KEEP]
exceeds the number of devices that can be registered (200 remote
cameras), “C/S OVER!” appears.
Auto IP setting can be executed even in this state, but IP addresses
will be set only for the number of devices that can be registered.
z
z
The unit may not be able to detect all of the remote cameras when,
for example, multiple remote cameras are started at the same time.
In this case, select [RETRY] in the [EXEC] item and press the F4 dial
to retry.
z
z
If the number of newly detected devices does not match the number
of devices that are to actually be set, such as if the power of the
remote camera was not on, etc., solve the problem, then select
[RETRY] in the [EXEC] item and press the F4 dial to retry.
z
z
When adding another remote camera controller (AW‑RP60 [this
unit]), set an IP address that is not a duplicate of any IP address
within the same network before making the connection.
z
z
Execute “auto IP setting” when devices not applicable for auto
IP setting (devices other than the remote cameras) are in a
non‑operation state in the same network. After executing “auto
IP setting”, connect these devices after checking that there is no
duplicate IP address within the same network.
Notes
Settings for connecting with the remote cameras
(continued)