32
When introducing additional remote cameras into an
environment in which IP connections are already in
use
The settings can be configured using “auto IP setting” even when
introducing additional remote cameras into an environment in which IP
connections are already in use.
There are the following two methods.
1. Automatically changing the IP address set on the additional
device to be introduced from the unit
2. Leaving the IP addresses of the additional devices to be
introduced unchanged and automatically updating the
connection destination IP addresses set on the unit
Automatically changing the IP address set on the
additional device to be introduced from the unit
<Overview of operation>
By executing [RENEW] in the [AUTO SET] item of the [AUTO IP SET]
SYSTEM menu, links are set.
With [RENEW], the unit first searches within the same subnet. Then,
links are set between the newly detected remote cameras and camera
numbers for which the connection type is set to [NON] on the unit.
At that time, the IP addresses of the remote cameras are overwritten
with the connection destination IP address values set on the unit.
Example:
(1) Operation is being performed with the three remote cameras A, B
and C set to CAM1, CAM2 and CAM3, respectively.
(2) The new remote camera D (with the following IP address value)
is added.
Remote camera D :
192.168.0.10
(3) Connection types set on the unit ([SYSTEM] > [CONNECT
SETTING])
CAM1 :
LAN
CAM2 :
LAN
CAM3 :
LAN
CAM4 :
NON
(4) Connection destination IP address set on the unit ([SYSTEM] >
[MANUAL IP SET/USER AUTH])
CAM4 :
192.168.0.13
When [RENEW] is executed in this state, the IP address of remote
camera D is overwritten with the following value, and a link is set to
the camera number CAM4.
Remote camera D :
192.168.0.13
192.168.0.13
192.168.0.10
192.168.0.13
Remote
camera A
Remote
camera B
Remote
camera C
CAM4
Remote
camera D
Connection destination IP
address of CAM4
z
z
When you connect a remote camera for which the IP address has
been changed using a personal computer or other device after a link
was set to the unit with auto IP setting and then execute [RENEW],
the same IP address as was set when auto IP setting was executed
the first time is set again for the corresponding camera.
<Operating procedure>
1.
Connect the additional remote cameras to be introduced
and the unit to the network within the same subnet.
2.
Select the [AUTO IP SET] SYSTEM menu, turn the F1
dial to display [RENEW], then press the F1 dial.
AUTO IP SET 1/1
AUTO SET
RENEW
NON
TOTAL
EXEC
NEW
AW-UE70
The number of devices currently being managed by the unit (All
remote cameras and the newly detected number of devices are
displayed in [NEW] and [TOTAL].)
NEW
:
Newly detected cameras
TOTAL :
The number of all devices currently being managed by
the unit + Number of newly detected devices
Settings for connecting with the remote cameras